CONNECTING SERIAL PTZ

The unit has two RS-485 ports on the rear panel. You can connect multiple PTZ devices in a daisy chain from either port. Be sure to disconnect power from any camera before connecting its data leads to the unit.

To connect the data leads from a serial PTZ device to the unit:

1.Using a small screwdriver (or similar tool), push in the TX– wire retainer on the first data port on the terminal block.

2.Insert the RX– data wire from the PTZ device into the TX– retainer.

3.Push in the TX+ wire retainer on the first data port on the terminal block.

4.Insert the RX+ data wire from the PTZ device into the TX+ retainer.

5.To connect a PTZ device to the second data port, repeat the previous steps, as necessary.

6.To connect additional PTZ devices in a daisy chain, refer to the documentation supplied with the PTZ devices.

NOTE: Maximum distance for serial communication lines is 1,219 m (4,000 ft) between the DX4700/DX4800 and the last PTZ device on the daisy chain.

Figure 7. Connecting a Serial PTZ Device

After installation, you need to configure the communication settings and the PTZ protocol for the unit as well as the PTZ device. The DX4700/DX4800 supports Pelco C, Pelco D (2-wire control only), Pelco P, and other PTZ protocols.

Table B. Supported PTZ Protocols

Protocol Name

Manufacturer

 

 

PELCO C

Pelco

 

 

PELCO D

Pelco

 

 

PELCO P

LG®

LG_MULTIX

LG

 

 

LG_SD168

LG

 

 

GANZ®_DSCP

CBC(America)

Protocol Name

Manufacturer

 

 

GANZ_P360V1

CBC

 

 

KALATEL_CYBERDOME

Kalatel

PANASONIC_CS850

Panasonic®

SAMSUNG_SCC

Samsung

BOSCH_AUTODOME

Bosch®

 

 

NOTE: Bosch and Panasonic do not support up-the-coax PTZ control.

For information about configuring the unit for PTZ operation, refer to the DX4700/DX4800 Series Server Operation/Configuration manual. For information about configuring the PTZ device, refer to the documentation supplied with the device.

C4675M (2/11)

17

Image 17
Contents DX4700/DX4800 Series Hybrid Video Recorder Contents List of Tables List of IllustrationsLegal Notice Important NoticesRegulatory Notices Video Quality CautionOpen Source Software Notice Client Application Software DescriptionModels Optional AccessoriesProduct Overview Package ContentsChannel and Camera Control Buttons System Status IndicatorsFront Panel Shuttle Dial outer ring Selection ControlPlayback Controls Monitor Selection Ethernet Adapter Port 100 Mbps port Rear PanelVGA Monitor Output 15-pin output PTZ Controls Remote ControlLens Controls ~ã Menu Controls~é Playback Controls Equipment Connections Overview InstallationEquipment Placement Cable Type Maximum Distance Connecting Analog CamerasConnecting IP Cameras Protocol Name Manufacturer Connecting Serial PTZConnecting Alarm Devices Connecting Alarm DevicesConnecting the Spot Monitor Connecting a Relay OutputConnecting the Main Monitor Connecting Audio Devices Connecting USB DevicesConnecting the Mouse Connecting to a NetworkMemory 256 MB Video 64 MB Installing Client SoftwareLogging on and Logging OFF Operation/ConfigurationUnit Startup Unit Shutdown Video SpecificationsAppendixes Appendix a Connecting ATM/POS DevicesAppendix B Connecting Audio Devices Product Warranty and Return Information