1.12 A-scope Display

This display shows echoes at each transmis- sion with amplitudes and tone proportional to their intensities, on the right 1/3 of the screen. It is useful for estimating the kind of fish school and bottom composition.

200k

0 0.0

10

Normal display

20

30

32.340

A-scope display

Figure 1-25 A-scope display

1.Press the A-SCOPE key. The A-SCOPE selection display appears.

A-SCOPE

OFF

ON

Figure 1-26 A-scope selection display

2.Press or to select OFF or ON.

3.Press the MENU ESC key.

1.13 User Menu

The User menu has several functions which require adjustment according to operating conditions.

1.Press the MENU ESC key to display the User menu.

OFF NL1 NL2 NL3

CLUTTER

AUTO 016

MARKER

VRM WHITE MARKER

HUE

11 9

GAIN ADJ 200kHz

0-20 +20 GAIN ADJ 50kHz

0-20+20

▲▼ : To select item

ts￿: To set condition

Figure 1-27 User menu

2.Press or to select menu item. As you operate or , the selected item and its current setting are displayed in yellow.

3.Press t or s to set condition.

4.Press the MENU ESC key to close the menu.

10

Image 18
Contents Page R 9 9 Safety Instructions Table of Contents Word to FCV-600L Owners FeaturesForeword IiiMenu Tree User MenuSystem Configuration FCV-600L system configurationPrinciple of Operation Underwater conditions and video sounder displayOperational Overview Control DescriptionIndications, Markers IndicationsSelecting a Display Turning On/Off the PowerAdjusting Tone and Brilliance Normal displayMarker-zoom display 49.628.2 Dual-frequency displayBottom-lock display Bottom-zoom display36.4 Data displayGraphic displays 69.4 mSelecting Display Range Adjusting the GainBasic ranges default settings Range shiftingSelecting Picture Advance Speed How to enable automatic operationAutomatic Operation How it worksErasing Weak Echoes Measuring DepthScope Display 32.3User Menu Selecting Background and Echo Colors Suppressing InterferenceSuppressing Low Level Noise Background and echo colorsAlarms Fine Adjustment of Gain in Dual-Frequency Operation White MarkerThis page is intentionally left blank Optional Mode Displaying the Optional Mode MenuSystem Menu System menu 1 description System menu 2 descriptionSystem menu 3 description Demonstration Display Bottom LevelTVG Level Echo OffsetFish School Echoes Interpreting the DisplayZero Line Bottom EchoSurface Noise/Aeration Surface noise/aerationTransducer Maintenance Maintenance & TroubleshootingCleaning the Display Unit CheckingTroubleshooting TroubleshootingTest Test PatternClearing the Memory Clear memory displaySpecifications of Color LCD Sounder Power Supply and Power Consumption