Furuno FCV-600L manual Troubleshooting

Page 30

4.5 Troubleshooting

The table below provides simple troubleshooting procedures which you may follow to restore normal operation. If you cannot restore normal operation, contact your dealer.

Table 4-2 Troubleshooting

If...

Then check...

 

 

neither echo nor fixed range scale

• battery voltage.

appears

• fuse.

 

• power supply.

 

• power cable.

 

 

no echo appears but fixed range

• if display advance speed is set to STOP .

scale appears

• transducer plug.

 

 

echo appears but no zero line

• if range shifting is set t o 0.

 

 

sensitivity is low

• gain setting.

 

• if air bubbles are present or marine life is stuck to

 

the transducer.

 

• if water is dirty.

 

• if bottom is too soft to return an echo.

 

 

there is extreme interference or

• if transducer or cable is close to engine.

noise

• if unit is properly grounded.

 

• if other echo sounders of the same frequency as own

 

are being operated nearby.

 

 

there is no or unrealistic

• sensor plug.

speed/temperature readout

 

 

 

there is no or unrealistic ship's

• connection between sounder and navigator.

position readout

• navigator itself.

 

 

22

Image 30
Contents Page R 9 9 Safety Instructions Table of Contents Word to FCV-600L Owners FeaturesForeword IiiMenu Tree User MenuSystem Configuration FCV-600L system configurationPrinciple of Operation Underwater conditions and video sounder displayOperational Overview Control DescriptionIndications, Markers IndicationsSelecting a Display Turning On/Off the PowerAdjusting Tone and Brilliance Normal displayMarker-zoom display 49.628.2 Dual-frequency displayBottom-lock display Bottom-zoom display36.4 Data displayGraphic displays 69.4 mSelecting Display Range Adjusting the GainBasic ranges default settings Range shiftingSelecting Picture Advance Speed How to enable automatic operationAutomatic Operation How it worksErasing Weak Echoes Measuring DepthScope Display 32.3User Menu Selecting Background and Echo Colors Suppressing InterferenceSuppressing Low Level Noise Background and echo colorsAlarms Fine Adjustment of Gain in Dual-Frequency Operation White MarkerThis page is intentionally left blank Optional Mode Displaying the Optional Mode MenuSystem Menu System menu 1 description System menu 2 descriptionSystem menu 3 description Demonstration Display Bottom LevelTVG Level Echo OffsetFish School Echoes Interpreting the DisplayZero Line Bottom EchoSurface Noise/Aeration Surface noise/aerationTransducer Maintenance Maintenance & TroubleshootingCleaning the Display Unit CheckingTroubleshooting TroubleshootingTest Test PatternClearing the Memory Clear memory displaySpecifications of Color LCD Sounder Power Supply and Power Consumption