Furuno FCV-600L manual Alarms

Page 20

1.17 Alarms

Bottom alarm

The bottom alarm sounds when the bottom is within the alarm range set. To activate the bottom alarm the depth must be displayed.

Fish alarm

There are two types of fish alarms: bottom- lock and normal. The bottom-lock fish alarm sounds when fish are within a certain distance from the bottom. The normal fish alarm sounds when fish are within the preset alarm range.

Water temperature alarm

There are two types of water temperature alarms: IN and OUT. The IN alarm sounds when the water temperature is within the range set; the OUT alarm sounds when the water temperature is higher than the range set. This alarm requires water temperature data.

Activating/deactivating an alarm

1.Press the ALARM key to display the alarm setting display and select alarm desired.

BOTTOM

 

 

OFF

ON

ALARM ZONE

 

 

 

5

 

0

RANGE

 

 

 

5

 

 

 

FISH (NORMAL)

 

ON

OFF

ALARM ZONE

 

 

0

5

RANGE

 

 

 

5

 

 

 

 

 

FISH (B/L)

 

 

 

ON

 

 

OFF

ALARM ZONE

 

 

22

21

RANGE

 

 

 

1

 

 

 

 

 

TEMP

 

 

 

 

 

OFF

IN OUT

ALARM ZONE

 

32

37

RANGE

 

 

 

5

▲▼ : To select item

ts: To set condition

Table 1-3 Alarm width data

Alarm

Alarm

Default

Width (m)

Setting (m)

 

 

 

 

Bottom

1-99

5

 

 

 

Fish-Normal

1-99

5

 

 

 

Fish-B/L

1-B/L value

1

 

 

 

Temp IN

1-99

5

 

 

 

Temp OUT

1-99

5

 

 

 

Figure 1-30 Alarm mode display

2. Press sto select ON.

Alarm

 

F/NM

 

 

 

 

 

Alarm

 

 

 

 

 

 

 

 

zone

 

 

 

 

 

 

 

 

zone

 

 

 

 

 

 

 

 

 

 

marker

 

 

 

 

 

 

 

 

(Fish,

 

 

 

 

 

bottom

 

 

 

 

 

alarms

 

 

 

 

 

only)

Figure 1-31 Alarm zone

3.Press to set ALARM RANGE.

4.Presstor sto change alarm zone as de- sired.

5 Press to set RANGE.

6.Presstor s to change range as desired.

7.To deactivate an alarm, select OFF.

Note : For fish alarm set “F/A LEVEL”. See page15.

Silencing the buzzer

The buzzer sounds whenever an alarm is vio- lated. You can temporarily silence the buzzer by pressing the ALARM key. However, the buzzer will sound whenever the alarm setting is violated.

12

Image 20
Contents Page R 9 9 Safety Instructions Table of Contents Features ForewordWord to FCV-600L Owners IiiMenu Tree User MenuSystem Configuration FCV-600L system configurationPrinciple of Operation Underwater conditions and video sounder displayOperational Overview Control DescriptionIndications, Markers IndicationsTurning On/Off the Power Adjusting Tone and BrillianceSelecting a Display Normal display49.6 28.2Marker-zoom display Dual-frequency displayBottom-zoom display 36.4Bottom-lock display Data displayGraphic displays 69.4 mAdjusting the Gain Basic ranges default settingsSelecting Display Range Range shiftingHow to enable automatic operation Automatic OperationSelecting Picture Advance Speed How it worksErasing Weak Echoes Measuring DepthUser Menu Scope Display32.3 Suppressing Interference Suppressing Low Level NoiseSelecting Background and Echo Colors Background and echo colorsAlarms Fine Adjustment of Gain in Dual-Frequency Operation White MarkerThis page is intentionally left blank System Menu Optional ModeDisplaying the Optional Mode Menu System menu 3 description System menu 1 descriptionSystem menu 2 description Demonstration Display Bottom LevelTVG Level Echo OffsetInterpreting the Display Zero LineFish School Echoes Bottom EchoSurface Noise/Aeration Surface noise/aerationMaintenance & Troubleshooting Cleaning the Display UnitTransducer Maintenance CheckingTroubleshooting TroubleshootingTest Test PatternClearing the Memory Clear memory displaySpecifications of Color LCD Sounder Power Supply and Power Consumption