Auto SPEP Timer

If, when recording in SP mode, there is not enough tape to record the entire program, the VCR automatically switches to EP mode to allow complete recording. This feature is especially handy when recording a program of more than 2 hours in length.

For Example . . .

Recording a program of 140 minutes in length onto a 120- minute tape

Approximately 110 minutes

Approximately 30 minutes

 

 

SP mode

EP mode

Total 140 minutes

Make sure you set "AUTO SPEP TIMER" to “ON” at the

Function screen before the timer recording starts.

 

 

ACCESS MAIN MENU

 

 

 

1

 

SCREEN

 

 

 

 

 

 

Press MENU.

 

 

 

 

 

 

 

ACCESS FUNCTION SET

2

 

SCREEN

 

 

 

 

 

 

Move the highlight bar (arrow) to "FUNCTION SET" by

 

pressing CH or SHUTTLE PLUS , then press OK

 

or SHUTTLE PLUS #.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SELECT AUTO SP EP

 

 

 

3

 

TIMER SET MODE

 

 

 

 

Move the highlight bar

 

FUNCTION

 

 

 

 

(arrow) to "AUTO SPEP

 

 

 

 

 

 

VIDEO CALIBRATION

ON

 

TIMER" by pressing CH

 

PICTURE CONTROL

AUTO

 

 

AUTO TIMER

OFF

 

 

or SHUTTLE PLUS

 

SUPERIMPOSE

ON

 

 

, then press OK or

 

 

 

 

 

 

=AUTO SP=EP TIMER

ON

 

 

 

SHUTTLE PLUS # to set to

 

VIDEO STABILIZER

OFF

 

 

 

"ON".

 

NEXT PAGE

 

 

 

 

 

SELECT WITH (5,°) AND (OK)

 

 

 

 

 

 

 

 

PRESS (MENU) TO END

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN TO NORMAL

 

 

 

4

 

SCREEN

 

 

 

 

 

 

Press MENU.

 

 

 

 

 

NOTES:

If you have programmed the VCR to timer-record 2 or more programs, the second program and those thereafter may not fit on the tape if you set the Auto SPEP Timer mode to "ON". In this case, make sure the mode is not engaged, then set the tape speed manually during timer programming.

In order to ensure that the recording fits on the tape, this feature may leave a slight non-recorded section at the end of the tape.

There may be some noise at the point on the tape where the VCR switches from SP to EP mode.

The Auto SPEP Timer feature is not available during ITR (Instant Timer Recording), and the feature will work with the following tapes: T(ST)-30, T(ST)-60, T(ST)-90, and T(ST)-120.

EN45

Auto Timer

When the Auto Timer is set to "ON" the timer is automatically engaged when the VCR's power is turned off. It is automatically disengaged when the VCR is powered back on.

 

 

ACCESS MAIN MENU

 

 

 

1

 

SCREEN

 

 

 

 

 

 

Press MENU.

 

 

 

 

 

 

 

ACCESS FUNCTION SET

2

 

SCREEN

 

 

 

 

 

 

Move the highlight bar (arrow) to "FUNCTION SET" by

 

pressing CH or SHUTTLE PLUS , then press OK

 

or SHUTTLE PLUS #.

 

 

 

 

 

 

 

SELECT AUTO TIMER SET

3

 

MODE

 

 

 

 

 

 

Move the highlight bar

 

FUNCTION

 

 

 

 

(arrow) to "AUTO TIMER"

 

VIDEO CALIBRATION

ON

 

by pressing CH or

 

PICTURE CONTROL

AUTO

 

 

=AUTO TIMER

OFF

 

 

 

SHUTTLE PLUS , then

 

SUPERIMPOSE

ON

 

 

 

press OK or SHUTTLE

 

AUTO SP=EP TIMER

ON

 

 

PLUS # to set to "ON" or

 

VIDEO STABILIZER

OFF

 

 

"OFF".

 

NEXT PAGE

 

 

 

 

 

SELECT WITH (5,°) AND (OK)

 

 

 

 

 

 

 

 

PRESS (MENU) TO END

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN TO NORMAL

 

 

 

4

 

SCREEN

 

 

 

 

 

 

Press MENU.

 

 

 

 

 

NOTE:

For safety, when AUTO TIMER is set to “OFF”, all other VCR functions are disabled while the Timer mode is engaged. To disengage the timer, press TIMER.

Image 45
Contents HR-S4600U HR-S3600U Do not place the VCR Dear CustomerPower Cord Protection Power SourcesPower Lines Grounding or PolarizationDamage Requiring Service AccessoriesCleaning Replacement PartsContents Connections Coaxial Cable Back of VCRMatching Transformer RF Cable suppliedPlug & Play Plug & Play SetupEN I Nitial Sett Ings Auto Clock Set/Auto Tuner SetInformation Language Clock Access Clock SETPreparation Pressing Shuttle PlusSET Auto Clock to on Select D.S.T. ModeSelect Host Channel Semi-AutoReturn to Normal Screen Select Time ZoneSET Time SET DateTuner Access Main Menu ScreenSET Set Receivable ChannelsAccess Manual ChannelAdd Or Delete a Channel Situate Controller Cable Box ControlAttach Controller Connect Cable BOX to VCRAccess Initial SET Screen Access Cable BOX SETTurn on Cable BOX Select Cable BOX Output ChannelAccess Cable BOX Brand SET Screen Enter Cable BOX BrandBrand Code DBS Receiver Control Connect DBS Receiver To VCRDBS receiver Turn on DBS Receiver Access DBS Receiver SETSelect DBS Receiver Output ChannelSET DBS Receiver Brand Access DBS ReceiverDBS Receiver Code from Following list, then Press OK JVC Dish Network Echostar Dish NetworkLoad a Cassette Simple PlaybackFind Program Start Point Start PlaybackSimple Recording Activate FRAME-BY Playback FeaturesFrame Playback EN Playba CK a ND Recording Feat UresEngage Manual Tracking Mode Access Distant CodeAdjust Manual Tracking Start SearchSET Mode Access Function SETLayback and Recording Features Picture ControlSelect The Soundtrack Video StabilizerFront AUX Input Stop Repeat Start RepeatMode SuperimposeSelect Superimpose SET Select Mode Access Skip MenuPerform Movie AdvanceExample AV Compu Link PlaybackPlayback and Recording Features Active Video CalibrationVideo Calibration Playback RecordingStart Playback Recording Features VHS Super VHS, S-VHS ET and VHS Layba CK and Recording Features Select S-VHS ET SETSuper VHS ET Stereo And SAP Second Audio ProgramTo Record SAP Programs EN Timer Recording VCR Plus+ Timer ProgrammingInput Receiving Channel Number Enter Pluscode NumberPlusCode number you Timer-Recording informaEntered and the matching Tion is displayed onVCR Plus+ Setup VCR Plus+ Guide Channel MatchingInitial SET, then press Access Guide Channel SET Screen Input Guide Channel NumberThen press OK or Shuttle Access VCR PLUS+ Express Timer ProgrammingSET Program Date SET Channel NumberEngage Timer Mode RE-ENGAGE Timer Cancel or Revise aCheck, Cancel And Revise Programs ProgramAuto SP→EP Timer Select Auto SP EP Timer SET ModeAuto Timer Or Shuttle PlusEngage ITR Mode Instant Timer Recording ITRSET Recording Duration Press REC on the front panelEngage Auto Satellite Prog REC Mode Automatic Sat- ellite Program RecordingBefore performing the following steps Editing Edit From a CamcorderRecorder PlayerSet your VCR to its record mode Pause connector whenFront AUX Input appears only with HR-S4600U Plus %Þto moveEdit To Or From Another Locate Start Point Audio DubbingEngage Audio Dubbing Start DubbingInsert Editing Reset the CounterLocate END Point EN EditingEND Insert Editing Start EditingTurn on the TV TV Multi-Brand Remote ControlSET TV Brand Code Operate TVTurn on the Cable BOX Cable Box Multi-Brand Remote ControlOperate Cable BOX Cable BOX Brand Name Brand CodeDBS Receiver Multi-Brand Remote Control EN Special FeaturesTurn on the DBS Receiver Enter DBS Receiver BrandUnplug Vcrs Power Turn VCR Power onSET Remote Control Plug in Power CordMake sure the cassettes window is Cassette gets stuck partwayTimer again Re-perform the VCR Plus+ setup Doesn’t work properlyProcedure Those in the previous area Other Problems TroubleshootingCan the VCR indefinitely remain in the still mode? Questions and Answer S E NCan the VCR indefinitely remain in the Record-Pause mode? What happens if the tape runs out during recording?MBR Multi-Brand Remote Code Setting Express Timer ProgrammingList Of Terms IndexFront View HR-S4600U Rear View EN IndexRemote Control 20C to 60C -4F to140F Year programmable timerFor Servicing Only in U.S.A HOW to Locate Your JVC Service CenterLimited Warranty Warranty Only in U.S.AMemo Memo Memo HR-S4600/S3600U