ELECTRICAL ADJUSTMENT
(5) C RECORD CURRENT
Adjustment Parts | Check Point | Measuring Equipment | Test Tape | Input Signal |
R492 | TJ491 | Signal Gen. Oscilloscope | Blank Tape | Color Bar |
|
|
|
|
|
vCONNECTION METHOD
R492 |
|
R491 | TJ491 |
| |
| |
TJ302 |
|
| |
| Oscilloscope |
| |
| SIGNAL |
| GENERATOR |
vADJUSTMENT PROCEDURE
1)Supply the Color Bar Signal to the VIDEO IN JACK, and set the VCR to the REC mode.
2)Connect the oscilloscope to TJ491 and trigger the scope with a composite sync signal at TJ302.
3)Adjust R491 until
4) Adjust R492 until color record current is 130 ± | Burst |
|
TJ491
130
11