ELECTRICAL ADJUSTMENT
(6) Y RECORD CURRENT
Adjustment Parts | Checking Point | Measuring Equipment | Test Tape | Input Signal |
R491 | TJ491 | Signal Gen. Oscilloscope | Blank Tape | Color Bar |
|
|
|
|
|
vCONNECTION METHOD
R491 | TJ491 |
| |
|
|
TJ302 |
|
| |
| Oscilloscope |
| |
| SIGNAL |
| GENERATOR |
vADJUSTMENT PROCEDURE
1)Supply the Color Bar Signal to the VIDEO IN JACK.
2)After Inserting a Rec Tape, Rec in SP MODE.
3)Connect the oscilloscope to TJ491
and trigger the scope with a compos- ite sync signal at TJ302.
4)Adjust R491 until
TJ491
500V
12