Seagate ST12550N/ND/W/WD, ST11950N/ND/W/WD manual Setting the Scsi ID on N- and ND-type drives

Page 23

ST11950 and ST12550 Installation Guide, Rev. D 21

Also check your system or controller user’s manual to ensure that you have not violated its SCSI ID numbering recommendations.

SCSI

 

Connector

 

DC Power

J01

Connector

 

Pin 1

 

J4

 

ID1

ID2

ID0

Select SCSI ID by placing jumpers as shown below. J4

SCSI ID = 0

SCSI ID = 1

SCSI ID = 2

SCSI ID = 3

SCSI ID = 4

SCSI ID = 5

SCSI ID = 6

SCSI ID = 7

Figure 3. Setting the SCSI ID on N- and ND-type drives

Image 23
Contents Barracuda 1 Disc Drive ST11950N/ND/W/WD ST12550N/ND/W/WD Contents Electrostatic discharge protection ST11950 and ST12550 Installation Guide, Rev. DImportant safety information and precautions Page ST11950 and ST12550 Installation Guide, Rev. D Wichtige Sicherheitshinweise Page Page Page Page SeaTDD 408 10 ST11950 and ST12550 Installation Guide, Rev. DSeaFAX USA 408 438-2620 England SeaFONE 408Location Number SeaBOARDTelephone General description 12 ST11950 and ST12550 Installation Guide, Rev. DBarracuda 1 and 2 disc drive N/ND type Characteristics ST11950N/ND ST11950W/WD 14 ST11950 and ST12550 Installation Guide, Rev. DCharacteristics ST12550N/ND ST12550W/WD Amps 16 ST11950 and ST12550 Installation Guide, Rev. DST11950 and ST12550 Installation Guide, Rev. D From previous 18 ST11950 and ST12550 Installation Guide, Rev. DInitial setup information Setting the Scsi ID jumpers 20 ST11950 and ST12550 Installation Guide, Rev. DSetting the Scsi ID on N- and ND-type drives Setting the Scsi ID on W- and WD-type drives 22 ST11950 and ST12550 Installation Guide, Rev. DScsi bus termination Terminating the driveST11950N and ST12550N drives Installing terminator packs ST11950N shownST11950W and ST12550W drives Enabling termination On ST11950W and ST12550W drives 26 ST11950 and ST12550 Installation Guide, Rev. DTermination is supplied Terminator powerChanging other applicable jumper options 28 ST11950 and ST12550 Installation Guide, Rev. DScsi Scsi I/O 30 ST11950 and ST12550 Installation Guide, Rev. DRES PAR DMS RES MTR WP Synchronizing spindles 32 ST11950 and ST12550 Installation Guide, Rev. DJ5 Pin ST11950N/ND ST12550N/ND Drives 34 ST11950 and ST12550 Installation Guide, Rev. DProviding adequate cooling Kühlung des Systems 36 ST11950 and ST12550 Installation Guide, Rev. DAbove unit Über der Einheit Under unit Unter der Einheit Mounting the drive and connecting cables 38 ST11950 and ST12550 Installation Guide, Rev. DInstallation des Laufwerkes und Anschluß der Kabel Dimensions Abbildung 15. Laufwerkabmessungen 40 ST11950 and ST12550 Installation Guide, Rev. DPage DC power connector Abbildung 16. Gleichstromanschluß Hinweis Page Formatting the drive