MicroBoards Technology LightScribe Series Microboards NET Configuration, Configuration Options

Page 8

DVD Premium Pro LightScribe Series

MICROBOARDS TECHNOLOGY, LLC

Microboards NET Configuration

The Microboards NET configuration allows you to connect multiple 10-drive tower duplicators. They can function together as a single duplicator with 10 drives per tower for ultra high-quantity production, or can operate independently as stand-alone duplicators, each copying from a different master.

It does not matter which tower is set as the Master; the only restriction is that one tower of the chain must have the NET cable connected to the Out port only. The last tower in the chain will only use the In port.

Configuration Options

To set the Multi-Tower configuration, turn on power

 

 

 

 

 

NET MASTER

 

 

NET MASTER

 

to all of the connected towers and wait for the

 

 

 

configuration options to be displayed, as shown to

YES: SET MASTER

 

 

NO: STANDALONE

 

 

 

 

 

 

the right.

Master Display alternates

 

The exact display message and configuration

between these messages

 

 

 

 

 

 

options on each tower will depend on the location of

NET SLAVE 1

 

NET SLAVE 1

 

that tower in the chain.

YES: SET MASTER

 

NO: STANDALONE

 

Once the configuration has been selected, you must

First Slave Display, additional Slave

 

either power cycle all towers or run the Net Reboot

towers show Slave number sequentially

 

on all Master towers to change the configuration.

 

 

 

 

 

 

 

 

NET SLAVE X

 

The display of any Master or Stand-Alone tower will initially read COPY

 

 

 

NO: STANDALONE

 

START when it is ready for duplication. The control panel on Slave towers

 

 

 

 

Final tower in chain

 

is disabled.

 

 

 

 

 

Basic Configuration

The most basic configuration would be to set the first tower as the Master with the remaining towers as Slaves. For this configuration, you would only need to press the YES button on the Master tower when the configuration options are showing.

NET

NET

NET

NET

NET

NET

Master

Slave 1

Slave 2

Slave 3

Slave 4

Slave 5

The result with a six-tower configuration is shown above. Only the reader and hard drive on the NET Master will be available as source drives.

Net Reboot and Basic Configuration

To run the Net Reboot, press either the ▲or ▼ button until the display reads SETUP. Press the YES button, then press either the ▲or ▼ button until the display reads NET REBOOT. Press YES and all towers will reboot.

8

Image 8
Contents DVD Premium Pro LightScribe Series Microboards TECHNOLOGY, LLC Table of Contents Microboards Statement Regarding Improper Duplication System Overview Unpacking your systemCopy Start Disc to Disc DVD Premium Pro LightScribe NET SeriesInstallation Requirements Power supplyConnecting Master and Slave Towers Microboards NET Configuration Configuration OptionsBasic Configuration Net Reboot and Basic ConfigurationAdvanced Configuration Net Reboot and Advanced ConfigurationNet Reboot and Stand-Alone Operation Loading mediaMain Menu Master DiscRegistering Data to the Hard Drive HDD Copy Disc to DiscPrinting Disc to Disc Copy Hard Drive HDD to Disc Registering Print Images to the Hard Drive HDDPrinting Hard Drive HDD to Disc Clearing the Hard Drive HDDSimulation Disc to Disc Erasing RW mediaError status in Track Extraction Track ExtractionSetup Menu KEYMode Select HDD SetupUpdate DVD WR SpeedLightScribe Template Labeler LightScribe Disc Publisher as the DriveError Codes Read Errors ASC AscqChanged Operating Definition Inquiry Data has Changed Write Errors Write ERROR-RECOVERED with Auto Reallocation Changed Operating Definition Inquiry Data has Changed Ovaerlapped Commands Attempted Erase Failure Specifications Firmware UpdatesSupported Formats Technical SupportRackmount Models Tower Models Stand-Alone and NET SeriesCanadian Department of Communications DOC Statement