External Control Device Setup
Set ID
Use this function to specify a monitor ID number.
Refer to ‘Real Data Mapping’. See page 82.
1.Press the MENU button and then use D / E button to select the SETUP menu.
2.Press the G button and then use D / E button to select SET ID.
3.Press the G button and then use D / E button to adjust SET ID to choose the desired monitor ID number. The adjustment range of SET ID is 1 ~ 99.
4.Press EXIT button to return to TV viewing or press MENU button to return to the previous menu.
SETUP
VIDEO
AUDIO
TIME
OPTION
LOCK
EZ Scan
Manual Scan
Channel Edit
DTV Signal
Channel Label
Main Input
Sub Input
Aux. Label
SET ID | G |
MENU Previous
1
Communication Parameters
• Baud rate : 9600 bps (UART) | • Stop bit : 1 bit |
• Data length : 8 bits | • Communication code : ASCII code |
• Parity : None |
|
* Use a crossed (reverse) cable. | Transmission / Receiving Protocol |
Command Reference List
| COMMAND 1 COMMAND 2 | DATA | |||
|
|
|
| (Hexadecimal) | |
|
|
|
|
| |
01. Power | k | a | 0 | ~ 1 | |
02. | Input Select | k | b | 0 | ~ 8 |
03. Aspect Ratio | k | c | 0 | ~ 15 | |
04. Screen Mute | k | d | 0 | ~ 1 | |
05. Volume Mute | k | e | 0 | ~ 1 | |
06. | Volume Control | k | f | 0 | ~ 64 |
07. | Contrast | k | g | 0 | ~ 64 |
08. | Brightness | k | h | 0 | ~ 64 |
09. | Color | k | i | 0 | ~ 64 |
10. Tint | k | j | 0 | ~ 64 | |
11. Sharpness | k | k | 0 | ~ 64 | |
12. OSD Select | k | l | 0 | ~ 1 | |
13. | Remote Control Lock Mode | k | m | 0 | ~ 1 |
14. | PIP/Twin | k | n | 0 | ~ 3 |
15. | PIP Position | k | q | 0 | ~ 3 |
16. Treble | k | r | 0 | ~ 64 | |
17. Bass | k | s | 0 | ~ 64 | |
18. | Balance | k | t | 0 | ~ 64 |
19. | Color Temperature | k | u | 0 | ~ 2 |
20. | PIP Input Source | k | y | 0 | ~ 3 |
21. ISM Method | j | p | 0 | ~ 2 | |
22. White Wash | j | q | 0 | ~ 1 | |
23. | Orbiter Time Setting | j | r | 1 | ~ FE |
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
*[Command 1]: First command to control the set. (j or k)
*[Command 2]: Second command to control the set.
*[Set ID]: You can adjust the set ID to choose desired monitor ID number in Setup menu. Adjustment range is 1
~99. When selecting Set ID ‘0’, every connected the TV is controlled. Set ID is indicated as decimal (1~99) on menu and as Hexa decimal (0x0~0x63) on transmission/receiving protocol.
*[DATA]: To transmit command data.
Transmit ‘FF’ data to read status of command.
*[Cr]: Carriage Return
ASCII code ‘0x0D’
* [ ]: ASCII code ‘space (0x20)’
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
*The Monitor transmits ACK (acknowledgement) based on this format when receiving normal data. At this time, if the data is data read mode, it indicates present status data. If the data is data write mode, it returns the data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
*The Monitor transmits ACK (acknowledgement) based on this format when receiving abnormal data from
Data 1: Illegal Code
2:Not supported function
3:Wait more time
24. Orbiter Pixel Setting |
| j | s | 1 ~A |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
COM- |
| COM- | DATA 0 | DATA 1 | DATA 2 | DATA 3 | |||
MAND 1 MAND 2 (Hexadecimal) (Hexadecimal) (Hexadecimal) (Hexadecimal) | |||||||||
|
|
|
|
|
|
|
|
| |
25. Channel Tuning | m | a | 01 ~ 87 | 01 ~ 87 | 00 ~ FE | 00 ~ FF | |||
26. Channel Add/Del | m | b | 00 ~ 01 |
|
|
|
|
|
|
27. Key | m | c |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Owner’s Manual 81