Peerless Industries PLAV 60-S, PLA 60-S manual Installation to Concrete Wall

Page 5

Installation to Concrete Wall

WARNING

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components.

Never exceed the Maximum UL Load Capacity of 175 lb (79 kg).

Never mount this product to metal studs.

IMPORTANT! Concrete must be 2000 psi density minimum.

1

Use wall plate (A), making sure that it is level, as a

template to mark holes. The top mounting slots should

be located .36" above the desired screen center for PLA 60 and PLA 60-S and .43" below the desired screen center for PLAV 60 and PLAV 60-S. Use the masonry bit to drill 5/16" (8 mm) dia. holes to a minimum depth of 3" (76 mm). Insert anchors in holes flush with wall as shown (right). Place wall plate (A) over anchors (W) and secure with 5/16 x 3" wood screws (O) and washers (P).

WARNING

Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Never tighten in excess of 80 in • lb (9 N.M.).

WARNING

1

concrete

 

 

surface

W

Drill hole(s) and insert anchor(s) (W)

2

mounting

 

plate

 

 

 

 

 

 

 

 

 

W

Place plate over anchor(s) (W) and secure with screw(s)(O)

3

Tighten all fasteners

Always attach concrete expansion anchors directly to load-bearing concrete.

Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing mate- rial. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. If plaster/ drywall is thicker than 5/8", custom fasteners must be supplied by installer (Not evaluated by UL).

O

W

P

 

 

INCORRECT

VIEW

mounting

concrete

 

plate

 

 

 

CUTAWAY

 

plaster/

 

drywall

 

 

 

CORRECT

mounting

concrete

plate

 

 

plaster/

 

drywall

A

5 of 9

ISSUED: 05-02-06 SHEET #: 202-9112-3 12-05-06

Image 5
Contents Maximum UL Load Capacity 175 lb 79 kg Accessories Tools Needed for AssemblyJP R IV U Skip to on Installation to Wood Stud WallIMPORTANT! Concrete must be 2000 psi density minimum Installation to Concrete WallDetail Assembly C I H For Plav 60 only