Installation to Solid Concrete and Cinder Block
WARNING
•When installing Peerless wall mounts on cinder block, verify that you have a minimum of
•Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
•Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.
Level and use wall plate as template to mark center
1 of holes. Drill two 5/16" (8 mm) dia. holes to a minimum depth of 2.5" (64 mm). Insert anchors (F) in holes flush with wall. Place wall arm assembly (AA) over anchor and secure with wood screws (D). Make sure wall arm is level, and tighten all fasteners.
WARNING
•Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.
•Never tighten in excess of 80 in. • lb (9 N.M.).
1 | concrete |
surface |
F
Drill holes and insert anchors (F).
2 | AA |
|
| D | F |
Place plate (AA) over anchors (F) and secure with screws (D).
CUTAWAY VIEW
•Always attach concrete expansion anchors directly to
•Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable (not evaluated by UL), the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).
3
Tighten all fasteners.
solid |
concrete |
INCORRECT |
| CORRECT | |
concrete | wall |
| concrete |
wall | plate |
|
|
plate |
|
| |
|
|
| |
|
|
| D |
plaster/ |
| plaster/ | AA |
drywall |
| drywall |
|
cinder |
block |
F
fig. 1.5
4 of 20 | ISSUED: |