Installation to Solid Concrete or Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica- tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.

1

Make sure that wall plate (AA) is level, use it as a

template to mark four mounting holes. The top

mounting hole should be 2.5" (65 mm) above the desired screen center as shown in fig. 1.1 on page 4. Drill four 1/4" (6 mm) dia. holes to a minimum depth of 2.5" (65 mm). Insert anchors (EE) in holes flush with wall as shown (right). Place wall plate over anchors and secure with #14 x 2.5" screws (DD). Level, then tighten all fasteners.

WARNING

Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

WARNING

Always attach concrete anchors directly to load- bearing concrete.

Never attach concrete anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable, the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tighten- ing screws. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.

1

concrete

 

 

surface

EE

Drill holes and insert anchors (EE).

2

AA

 

 

 

 

DD

EE

Place plate (AA) over anchors (EE) and secure with screws (DD).

3

Tighten all fasteners.

solid

concrete

 

 

EE

cinder

block

AA

 

 

 

 

 

 

 

 

INCORRECT

VIEW

wall

concrete

plate

 

 

 

CUTAWAY

 

plaster/

 

dry wall

 

 

 

CORRECT

wall plate

concrete

 

plaster/

 

drywall

DD

5 of 24

ISSUED: 10-31-07 SHEET #: 202-9242-2 03-20-08

Visit Peerless website at www.peerlessmounts.com

For customer care call 1-800-729-0307 or 708-865-8870

Image 5
Contents Maximum UL Load Capacity 150 lb 68 kg Model PT640 FeaturesTable of Contents Tools Needed for AssemblyAccessories Adapter Bracket Fasteners DD AA Installation to Double Wood Stud WallCorrect Installation to Solid Concrete or Cinder BlockCenter Brackets Vertically on Back of Screen Handlesface OUT For Flat Back Screen Mounting and Removing Flat Panel Screen Adjusting the Tilt Angle of the Flat Panel ScreenCaracterísticas Máxima capacidad de carga UL 150 lb 68 kg Modelos PT640Advertencia Sujetadores para los soportes adaptadores Instalación en una pared con montantes de madera dobles Macizo Instalación de los soportes inclinables BbccPantalla Arandela Tornillo Sección Modèles PT640 Installation et assemblageAvertissement AA BB CC Fixations du support adaptateur Installation sur un mur à doubles montants en bois Plein Installation des supports adaptateurs Pour les écrans à dos plat Réglage de l’inclinaison de l’écran plat Plan Détaillé