Peerless Industries SP 850P-S, SP 850-S manual Installation to Solid Concrete and Cinder Block Wall

Page 5

Installation to Solid Concrete and Cinder Block Wall

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard- ware and components.

2

Position wall mount assembly (A) at desired position on

1

 

wall. Use wall mount assembly, making sure that it is

concrete

 

level, as a template to mark holes. Drill four 1/4" (6 mm)

 

wall

 

dia. holes to a minimum depth of 2-1/2" (64 mm). Con-

 

 

 

crete must be 2000 psi density minimum. Insert anchors

 

E

 

(E) in holes flush with wall as shown in figure 2.4. Place

 

 

wall mount assembly over anchors and secure with #14 x

 

 

 

2-1/2" (6 mm x 65 mm) wood screws (D) as shown in

Drill holes and insert anchors

 

figure 2.5. Make sure wall plate is level and tighten all

 

 

 

 

fasteners.

2

A

 

WARNING

 

 

 

• Tighten wood screws firmly, but do not overtighten.

D

E

 

Overtightening can damage the screws, greatly

 

 

 

reducing their holding power.

Place wall plate (A) over anchors and secure with

Never tighten in excess of 80 in • lb (9 N.M.).

screws (D)

 

3

WARNING

• Concrete anchors are not intended for attachment to

 

 

 

 

concrete wall covered with a layer of plaster, drywall,

Tighten all fasteners

 

 

 

or other finishing material as shown below. If mounting

 

 

 

to concrete wall covered with plaster/drywall is

 

fig 2.4

 

 

 

unavoidable, plaster/drywall (up to 5/8" thick) must be

 

 

 

SOLIDCONCRETE

 

 

 

counterbored as shown below. Be sure concrete

 

 

 

 

anchors do not pull away from concrete when tighten-

CINDER

 

 

ing screws. If plaster/drywall is thicker than

 

BLOCK

 

 

 

 

 

 

5/8", custom fasteners must be supplied by installer.

E

 

VIEW

 

CORRECT

INCORRECT

 

D

 

 

A

concrete

A

concrete

 

 

CUTAWAY

 

 

 

 

 

 

 

plaster/

plaster/

 

A

 

 

 

 

dry wall

dry wall

 

 

 

 

 

 

 

 

fig 2.5

 

 

 

 

 

 

5 of 10

ISSUED: 10-12-05 SHEET #: 202-9038-6 05-19-07

Image 5
Contents Models SP 850, SP 850P, SP 850-S, SP 850P-S Table of Contents Tools Needed for AssemblyEAA Installation to Wood Stud Wall Custom fasteners must be supplied by installer Installation to Solid Concrete and Cinder Block WallFor Vesa 100 Mounting Pattern For Installing to Vesa 100 MM, 200 MM Hole PatternFor Screens with Vesa Mounting Pattern in a Pocket For Vesa 200 Mounting PatternTilt Roll can be adjusted 1 clockwise or Manufacturer Screen Manufacturer Model Size Screen Compatibility Chart