Sim2 Multimedia 55M specifications Get Codes

Page 10
Get Codes

SIM2 DOMINO 55M RS-232C CONTROL SPECIFICATIONS

8

9

10

11

12

13

 

 

 

 

 

 

14 15 16 17 18 19 20

Op Type

Op ID

01

00

Op Target

00

00

Value

00

00

 

21

 

 

22

 

 

23

 

 

24

 

 

25

 

 

26

 

 

27

 

 

28

 

 

29

 

 

30

 

 

31

 

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

Get Codes

Get Commands may be used to get the current value of DOMINO 55M parameters.

The response to a correct Get Command consists of 33 byte packet, where Byte Number 11 contains the Validation Code (01) and bytes Number 17 and Number 18 the requested value (the least-significant byte of the value being sent first). Of course CRC (bytes number 6 and 7) has been altered accordingly.

0

1E

1

BE

2

EF

3

Packet Type

45

Packet Payload Size

67

Packet Checksum (CRC)

8

9

10

11

12

13

 

 

 

 

 

 

14 15 16 17 18 19 20

Op Type

Op ID

01

00

Op Target

00

00

Req Value

00

00

 

21

 

 

22

 

 

23

 

 

24

 

 

25

 

 

26

 

 

27

 

 

28

 

 

29

 

 

30

 

 

31

 

 

32

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

00

 

 

 

Get Codes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 52 2A 02 00 08 00 00 00 00 00 00

 

(1)

 

 

BRIGHTNESS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 C7 77 02 01 08 00 00 00 00 00 00

 

(1)

 

 

CONTRAST

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 38 93 02 02 08 00 00 00 00 00 00

 

(2)

 

 

COLOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 AD CE 02 03 08 00 00 00 00 00 00

 

(3)

 

 

TINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 9D 0B 02 C2 09 00 00 00 00 00 00

 

(4)

 

 

COLOR TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 13 25 02 27 08 00 00 00 00 00 00

 

(5)

 

 

GAMMA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BE EF 03 19 00 5E D5 02 27 09 00 00 01 00 00 00

 

(6)

 

 

MEMORY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Image 10
Contents RS-232C CONTROL SPECIFICATIONS DOMINO 55MCOMMANDS Revision HistoryTable of Contents INTRODUCTIONSIM 2 DOMINO 55M E-LINK RS-232C Control Port 1. Introduction2. Connection Communication ParametersPayload 3. Communication ProtocolHeader Event Packet FormatRemote Control Key Codes 4. CommandsRemote Control Keycodes Goto Contrast Direct access codesGoto Brightness Goto ColorOperation Codes Operation CodesRS-232C CONTROL SPECIFICATIONS SIM2 DOMINO 55Mbyte number 11 is set at CRC bytes number 6 and 7 has been altered accordinglyGet Codes Get CodesGamma 5. ExamplesColor Temperature Memory6. Warnings 4. Select INPUT 3 COMP RGB 1 WITH YcrCb 15kHz SIGNAL Send the packet3. Send the SET ASPECT ANAMORPHIC Operation Code. Send the packet