Sim2 Multimedia 55M specifications Examples, Color Temperature, Gamma, Memory

Page 11
Color Temperature

SIM2 DOMINO 55M

RS-232C CONTROL SPECIFICATIONS

(1)Returned value is indeterminate when the unit is in No Signal state.

Returned value may be different from the value displayed on the OSD, as in the latter, the values have been normalized to the 0-100 range.

(2)Returned value is valid only when Video, S-Video, RGBS 15 kHz, YCrCb 15 kHz or YcrCb 32 kHz signals are displayed. Returned value is indeterminate when other signals are displayed and when the unit is in No Signal state.

(3)Returned value is valid only when Video (NTSC), S-Video (NTSC), RGBS 15 kHz, YCrCb 15 kHz signals are displayed. Returned value is indeterminate when other signals are displayed and when the unit is in No Signal state.

(4)Table below associates OSD labels with returned values:

Color Temperature

OSD

Returned

Label

value

High

24

Medium

25

Low

26

User

27

(5)Table below associates OSD labels with returned values:

Gamma

 

 

OSD

 

Returned

 

 

 

Label

 

value

 

 

 

Film

 

10

 

 

 

Film 1

 

0B

 

 

 

Video

 

0D

 

 

 

Video 1

 

0F

 

 

 

Graphics

 

0C

 

(6)

Table below associates OSD labels with returned values:

 

 

 

Memory

 

 

 

 

OSD

 

Returned

 

 

 

Label

 

value

 

 

 

0 (Auto)

 

00

 

 

 

1

 

01

 

 

 

2

 

02

 

 

 

3

 

03

 

5. Examples

1.Send the simulated "SWITCH ON FROM STAND-BY AND SELECT SOURCE" Remote Control keycode.

Remote Control allows Switching on from Stand-by via one of the keys "1", "2" ... "7". Send, for instance, the code relative to key "1":

BEEF02060080E5490100000000.

The DOMINO 55M switches on and selects Input 1.

The DOMINO 55M returns the response code: 06 (Acknowledged with no error).

NOTE: Commands that simulate keys "1", "2" ... "7" switch on the unit and select the corresponding Source.

11

Image 11
Contents DOMINO 55M RS-232C CONTROL SPECIFICATIONSINTRODUCTION Revision HistoryTable of Contents COMMANDSCommunication Parameters 1. Introduction2. Connection SIM 2 DOMINO 55M E-LINK RS-232C Control PortEvent Packet Format 3. Communication ProtocolHeader PayloadRemote Control Keycodes 4. CommandsRemote Control Key Codes Goto Color Direct access codesGoto Brightness Goto ContrastOperation Codes Operation CodesSIM2 DOMINO 55M RS-232C CONTROL SPECIFICATIONSCRC bytes number 6 and 7 has been altered accordingly byte number 11 is set atGet Codes Get CodesMemory 5. ExamplesColor Temperature Gamma3. Send the SET ASPECT ANAMORPHIC Operation Code. Send the packet 4. Select INPUT 3 COMP RGB 1 WITH YcrCb 15kHz SIGNAL Send the packet6. Warnings