Sim2 Multimedia 55M Warnings, Send the SET ASPECT ANAMORPHIC Operation Code. Send the packet

Page 12
3.Send the "SET ASPECT ANAMORPHIC" Operation Code. Send the packet:

SIM2 DOMINO 55M

RS-232C CONTROL SPECIFICATIONS

Command that simulate key 0 switches on the unit: the last source memorised prior to switch off is automatically selected.

2.Send the simulated "MENU RIGHT" Remote Control keycode. Send the packet:

BEEF02060023E75A0100000000.

The OnScreen Display appers on the screen.

The DOMINO 55M returns the response code: 06 (Acknowledged with no error).

3.Send the "SET ASPECT ANAMORPHIC" Operation Code. Send the packet:

BEEF0206009DF5840100000000.

The Aspect Ratio changes to Anamorphic.

The DOMINO 55M returns the response code: 06 (Acknowledged with no error).

4.Select "INPUT 3 (COMP RGB 1) WITH YcrCb 15kHz SIGNAL" Send the packet:

BEEF0319005B0C01820800000000000008000000000000000000000000000000

Wait for the return code and add an additional delay of 50 ms.

Send the the code relative to the Key to which Input 3 has been assigned: for instance if the key is "3" the code is:

BEEF02060062E44B0100000000

6. Warnings

When the number of bytes sent to the DOMINO 55M is greater than indicated for the Command (32 bytes for Operation Packets and 13 bytes for Event Packets), excess data will be ignored.

Conversely, if number of bytes sent to the DOMINO 55M is smaller than required by the Communication Protocol, the command may be ignored.

Command execution time may vary from few milliseconds to 500 milliseconds, depending on the operation that have been requested.

If the unit is busy when a command is sent, the unit may not accept the command. If several commands are to be sent one after the other, sufficient time between them should be allowed.

12

Image 12
Contents RS-232C CONTROL SPECIFICATIONS DOMINO 55MRevision History Table of ContentsCOMMANDS INTRODUCTION1. Introduction 2. ConnectionSIM 2 DOMINO 55M E-LINK RS-232C Control Port Communication Parameters3. Communication Protocol HeaderPayload Event Packet Format4. Commands Remote Control Key CodesRemote Control Keycodes Direct access codes Goto BrightnessGoto Contrast Goto ColorOperation Codes Operation CodesRS-232C CONTROL SPECIFICATIONS SIM2 DOMINO 55Mbyte number 11 is set at CRC bytes number 6 and 7 has been altered accordinglyGet Codes Get Codes5. Examples Color TemperatureGamma Memory4. Select INPUT 3 COMP RGB 1 WITH YcrCb 15kHz SIGNAL Send the packet 6. Warnings3. Send the SET ASPECT ANAMORPHIC Operation Code. Send the packet