Black Box ME758C-RJ45 S2 Position 3 V.52 and V.54 Diagnostic Testing, S2-6 Signaling-Rate Range

Page 15

MULTI-FUNCTION LD CARD

S2 Position 3: V.52 and V.54 Diagnostic Testing

To reset the V.54 circuit, turn switch S2 position 3 ON, then back OFF.

S2-3

Test Mode

Off

Normal Operation (default)

On

Test Disabled

S2 Positions 4 and 5: RTS/CTS Delay

Set positions 4 and 5 of switch S2 to determine the amount of time the Multi- Function LD Card waits after it “sees” RTS before it sends CTS. Possible settings are no delay, 7 ms, or 53 ms.

S2-4

S2-5

RTS/CTS Delay

On

On

7 ms (default)

On

Off

53 ms

Off

On

No delay

Off

Off

No delay

S2-6: Signaling-Rate Range

Set position 6 of switch S2 to determine the degree of asynchronous data-rate fluctuation that the Multi-Function LD Card will accept (that is, how much variance from a given frequency level the Card will tolerate).

S2-6

Signaling-Rate Range

Off

-2.5% to +1% (default)

On

-2.5% to +2.3%

S2-7 and S2-8: Word Length

Set positions 7 and 8 of switch S2 to determine the word length that the Multi- Function LD Card will expect for synchronous or asynchronous data. For example, if you are using the most common data format (1 start bit,

8 data bits, 1 stop bit, and no parity), you would use the factory-default word- length setting (10 bits).

S2-7

S2-8

Word Length

On

Off

8 bits

On

On

9 bits

Off

Off

10 bits (default)

Off

On

11 bits

14

Image 15
Contents Multi-Function LD Cards FCC Statements MULTI-FUNCTION LD Card NOM Statements Contents Specifications Indicators DiagnosticsConnectors Fuse PowerTemperature WeightFeatures IntroductionOverview Introduction Main-module switches Setting the Switches on the Main ModuleSwitch S1 Summary On and OFF settings of the DIP switchesS1 Positions 1 through 4 Data-Rate Setting S1 Positions 5 and 6 Clock SourceS1 Position 7 Protocol Switch S2 Summary S2 Position 2 2-Wire vs -Wire OperationS1 Position 8 Carrier-Control Method S2-7 and S2-8 Word Length S2 Position 3 V.52 and V.54 Diagnostic TestingS2 Positions 4 and 5 RTS/CTS Delay S2-6 Signaling-Rate RangeS3-1 and S3-2 Input Impedance Switch S3 SummaryS3-6 DTE RS-232 Initiation of Remote Loopback Test Recommended Impedance SettingsS3-4 Mode Selection S3-5 DTE RS-232 Initiation of Local Loopback TestS3-7 and S3-8 Antistream Control Setting the Jumpers on the Interface ModuleFour interface modules Jumper locations Line Interface Line Shield Connection to Frame Ground JB2 Summary of Interface-Module Jumper FunctionsJB5 Serial Interface Signal Ground and Frame Ground JB4MicroRacks An Overview InstallationMicroRacks’ Power Supply Installing the Multi-Function LD Card in the MicroRack RS-232 Serial Cables and Connectors Pinout of the RS-232 InterfacePinout of the 10-Pin RJ Interface Modem-to-Modem Line Cables and Connectors AT&T standard modular color codes Line-Cable PinoutsMultipoint Applications Two-pair star wiring for host and slave CardsStatus LEDs Operation and DiagnosticsRTS and CD Indicators Diagnostic Testing Using the Error LED Power-Up V.54 and V.52 Diagnostic Tests Remote Digital Loopback RDL Using the V.52 Bert Test Independently Troubleshooting Calling Your SupplierShipping and Packaging Appendix Cable Recommendations Wire Gauge Capacitance ResistanceMULTI-FUNCTION LD Card Copyright 1995. Black Box Corporation. All rights reserved