Black Box ME758C-RJ45, ME759C-RJ45, May-95, ME759C-RJ11, ME758C-RJ11 manual Jumper locations

Page 20

CHAPTER 3: Configuration

3.2.3WHERE THE JUMPERS ARE

Figure 3-5, below, shows the locations of the jumpers on the interface modules (the locations are the same for both the -RJ11 and -RJ45 models). These jumpers determine various grounding and signal characteristics for the serial and modem-to-modem lines.

JB2

(peg 1 on left)

ME758C interface

module

JB2

(peg 1 on top)

ME759C interface

module

JB3

(peg 1 on top)

JB4

(peg 1 on left)

JB3

(peg 1 on top)

JB4

(peg 1 on left)

Figure 3-5. The jumper locations.

19

Image 20
Contents Multi-Function LD Cards FCC Statements MULTI-FUNCTION LD Card NOM Statements Contents Specifications Connectors IndicatorsDiagnostics Power TemperatureWeight FuseOverview FeaturesIntroduction Introduction Setting the Switches on the Main Module Main-module switchesOn and OFF settings of the DIP switches Switch S1 SummaryS1 Position 7 Protocol S1 Positions 1 through 4 Data-Rate SettingS1 Positions 5 and 6 Clock Source S1 Position 8 Carrier-Control Method Switch S2 SummaryS2 Position 2 2-Wire vs -Wire Operation S2 Position 3 V.52 and V.54 Diagnostic Testing S2 Positions 4 and 5 RTS/CTS DelayS2-6 Signaling-Rate Range S2-7 and S2-8 Word LengthSwitch S3 Summary S3-1 and S3-2 Input ImpedanceRecommended Impedance Settings S3-4 Mode SelectionS3-5 DTE RS-232 Initiation of Local Loopback Test S3-6 DTE RS-232 Initiation of Remote Loopback TestSetting the Jumpers on the Interface Module S3-7 and S3-8 Antistream ControlFour interface modules Jumper locations Summary of Interface-Module Jumper Functions Line Interface Line Shield Connection to Frame Ground JB2Serial Interface Signal Ground and Frame Ground JB4 JB5Installation MicroRacks An OverviewMicroRacks’ Power Supply Installing the Multi-Function LD Card in the MicroRack Pinout of the 10-Pin RJ Interface RS-232 Serial Cables and ConnectorsPinout of the RS-232 Interface Modem-to-Modem Line Cables and Connectors Line-Cable Pinouts AT&T standard modular color codesTwo-pair star wiring for host and slave Cards Multipoint ApplicationsOperation and Diagnostics Status LEDsRTS and CD Indicators Diagnostic Testing Using the Error LED Power-Up V.54 and V.52 Diagnostic Tests Remote Digital Loopback RDL Using the V.52 Bert Test Independently Shipping and Packaging TroubleshootingCalling Your Supplier Wire Gauge Capacitance Resistance Appendix Cable RecommendationsMULTI-FUNCTION LD Card Copyright 1995. Black Box Corporation. All rights reserved