| Mounting Requirements |
|
|
|
|
|
|
|
|
|
|
|
|
| SENC 150 |
|
|
| |||||||||||||
|
| Mounting options can be adapted to machine mounting surfaces |
|
|
|
|
| Center support |
|
|
|
|
|
| ||||||||||||||||||
|
| using spacers, standoffs, or leveling set screws. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
| • Measuring length and mechanical configuration of your |
|
|
|
|
|
|
| Support washer |
|
|
| |||||||||||||||||||
|
|
| machine determine your options. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Scale |
|
|
| |||||||||||
|
| • Backup spar mounting is an option but not required for lengths | .94 [23.8] |
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
|
|
| up to 60”. |
|
|
|
|
|
| washer |
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
| • Fastener lengths described on this page are included with the |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
| encoder or the backup spar. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| End hole mounting |
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| with center support |
|
|
|
| Typical (supplied) |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| • 24” to 60” : Use end mounting holes with center support. |
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| End hole mounting |
|
| Backup spar mounting |
|
|
|
| M4 x 8mm SHSS |
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (supplied) |
|
|
|
| |
& scale washer (supplied) |
|
| |
| & spar washer (supplied) |
• Less than 24” : Use end mounting holes. | • Over 60” : A backup spar is required. |
|
|
| 8 |
10/22/2009 10:00:42 AM