Acu-Rite 150 manual Senc Mechanical Specifications, Mechanical Specifications Digital Analog

Page 19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SENC 150

 

 

 

 

 

 

 

 

 

Mechanical Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical Specifications

 

 

Digital

 

 

 

 

Analog

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Resolution

0.5 µm

 

1 µm

 

5 µm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grating pitch

 

 

20 µm

 

 

 

 

20 µm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scale medium

 

 

Light transmission reflective off of nickel coated glass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy (@ 20° C) / 1000mm

 

 

 

 

 

 

± 3µm, ± 5µm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. slew speed

 

 

 

 

 

 

40 inches/sec

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Force required to move

 

 

 

 

 

 

< 0.75 lbs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reading head

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Environment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

0° to 50° C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relative Humidity

 

 

 

 

 

 

25% to 95% (non-condensing)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storage Environment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

 

 

 

 

 

- 20° to 70° C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Humidity

 

 

 

 

 

 

20% to 95% (non-condensing)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Weight w/armor

 

 

 

 

 

1.4 + 0.5 lbs/in of measuring length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connecting cable

 

 

 

 

 

 

Length = 5, 13, and 19 ft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

armored or vinyl

 

 

 

 

 

 

Connector: DE-9P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. cable length

 

 

35 ft

 

 

 

 

70 ft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring lengths

 

 

 

 

 

 

2” - 120”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference pulse interval

 

 

 

 

 

 

50mm fixed or Position-Trac TM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating current

 

220 ma

 

180ma

 

 

 

75ma

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protection (IEC 529)

IP 53 when installed as per instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP 64 with air Purge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

ACU-RITE®

516291-21_Ve00_SENC_150.indd 19

10/22/2009 10:00:47 AM

Image 19
Contents ACU-RITE 516291-21Ve00SENC150.indd 10/22/2009 100037 AM Brackets Senc Table of ContentsIntroduction / Supplied Items Senc ContentsCable direction Senc Mounting PreparationAlignment bracket removal clearance Mounting Information SencSenc Encoder Dimensions ± .381 127.00 typ. ± Backup Spar Dimensions mm SencSenc Backup Spar Dimensions inch With center support End hole mounting Backup spar mountingMounting Requirements Senc End hole mountingSenc Typical Mounting s Backup spar with bracketFlush surfaces Offset surfaces Center mounting axis Encoder Installation Procedure SencAlignment bracket removal Senc Encoder Installation ProcedureSpar Installation Procedure Senc Senc Spar Installation Procedure Counting Test Checking Your Installation Senc ConnectingRepeatability Test Electrical Shielding Trouble Shooting Senc Mechanical Specifications Digital Analog Senc Mechanical SpecificationsOutput Signals and Pin-Outs Senc Output Signals Senc Electrical SpecificationsWarranty Senc 516291-21Ve00SENC150.indd 10/22/2009 100047 AM Heidenhain Corporation