5.3.9. Upgrade RA & DEC

Use this operation to upgrade 8408 hand controller, R.A. and DEC motor controller firmware. Please refer to iOptron online documents for ZEQ25 firmware upgrade details. The password is 9999.

5.4. Align

This function is used for aligning the telescope. The hand controller provides “Polar Align”, which uses a set of 2 bright stars for polar alignment. This provides a viable polar alignment approach for those who can’t see the polar star or has a mount does not equip an iOptron AccuAlignTM polar scope. The system also provides three alignment methods: “SolarSys Align”, “One Star Align”, and “Multi-Star Align”. The mount has to be at Zero Position before performing any star alignment.

5.4.1. Polar Alignment

Press the MENU button, then select “Align” and “Polar Align”. The HC will display the azimuth and altitude position of several bright stars near meridian. Select one that is visible with high altitude as Alignment Star A. Follow the HC instruction to move the Star A to the center of the eyepiece with the combination of Latitude Adjustment Knob and “◄” or “►” button. Press ENTER to confirm. Next, select a bright star that is close to the horizon as the Alignment Star B. Center it using the Azimuth Adjustment Knob and “◄” or “►” button (The “▲” and “▼” buttons are not used here). Press ENTER to confirm.

The telescope will now slew back to Star A to repeat above steps. The iteration can be stopped when it is determined that the alignment error is at the minimum. Press BACK button to exit alignment procedure.

NOTE: It is highly recommended to use an eyepiece with crossed-hair line for accurate centering.

NOTE: The movement of the alignment star in your eyepiece may not be perpendicular but crossed, depends on its location in the sky.

5.4.2. SolarSys Alignment

Press MENU button and select “Align”. Select “SolarSys Align” and press ENTER for available alignment object.

5.4.3. One-Star Alignment

Press MENU button and select “Align”. Select “One Star Align” and press ENTER. A list of alignment stars that are above the horizon is computed based on your local time and location. With the mount at the “Zero Position,” use ▲ and ▼ buttons to select a star and press ENTER. Center the target in your eyepiece using arrow key. Press ENTER when finished. If your mount is well set up and polar aligned, one star alignment should be sufficient for good GOTO accuracy. To increase the accuracy you may choose to do multi star alignment.

5.4.4. Multi-Star Alignment

With iOptron’s multi-star alignment, you can choose two, three, or as many stars as you want to reduce the mount alignment offset.

Press MENU button and select “Align”. Select Multi-Star Align” in the align menu. A list of alignment stars that are above the horizon is computed based on your local time and location. With the mount is at the “Zero Position,” use ▲ and ▼ buttons to select first alignment star and press ENTER. Center the target in your eyepiece using arrow key. Press ENTER when finished. The hand controller will prompt you to choose the second star. If the star you choose is too close to the first one, the system will let you choose another one. When you are aligned with the second star, the two star alignment is finished. You can reject the suggested star if it is blocked by a tree or other obstruction.

25

Image 25
Contents IOptron ZEQ25GT Balanced GoTo Equatorial Mount Table of Content Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty ZEQ25GT Overview FeaturesZEQ25 Terms Parts List1ZEQ25 assembly terms mount and tripod Assembly TermsGo2Nova 8408 Hand Controller ZEQ25 PortsLCD Screen Key DescriptionSlew Speed Current Time ZEQ25 Mount Assembly ZEQ25GT Mount AssemblyIntroduction Select Mount Latitude Range Tripod SetupInstall Counterweight CW Shaft Adjust LatitudeAttach the ZEQ25 Mount Attach and Balance an OTA on the Mount Connect Cables Install CounterweightSetup Hand Controller Important Notes on Tension AdjustersConnect Cables Set Local Time Polar Alignment Set Observation Site CoordinateQuick Polar Alignment Return Mount to Zero Position BrightStar Polar AlignmentZero position Getting Started Setup the Mount and Polar AlignmentManual Operation of the Mount Initial Star AlignmentStar Identifying Function Gear Tension AdjustmentTurn Off the Mount Slew to an Object Complete Functions of Go2Nova 8408 Hand ControllerSync to Target Set Up ControllerTrack Below Horizon Meridian TreatmentSet Polar Light Firmware InformationAlign Set User Objects PEC OptionPole Star Position PEC PlaybackTo Zero Position Set Guide RateMaintenance Maintenance and ServicingIOptron Customer Service Battery Replacement and Disposal InstructionsGPS Appendix A. Technical SpecificationsMenu Appendix B. Go2Nova 8408 HC Menu StructurePage Appendix C. Firmware Upgrade Appendix D. Computer Control an ZEQ25GT Mount Messier Catalog Appendix E. Go2Nova Star ListNamed Star List Modern Constellations Deep Sky Object List Double Star List SAO Atik Ioptron TWO Year TELESCOPE, MOUNT, and Controller Warranty