Note: Do not mount the MRKP1E in the same electrical back- box as high

voltage devices such as electrical outlets or switches.

(See specifications)

3. Connections

MRKP1E to MRC88m and Expansion Keypads

Each RJ-45 connector under each PREAMP OUT (1 – 8) is considered a “Zone port”. This Zone port interfaces with MRKP1E Keypad through CAT-5 cables. These connectors carry command/control information between the keypad and the MRC88m. Connect CAT-5 cables terminated to an RJ-45 connector from each Keypad to the corresponding RJ45 connector of the MRC88m as shown below. (See Specifications section for maximum length of Cat-5 cables)

ZONE 4

IR EMITTER

ZONE 1

IR EMITTER

MRC88M REAR

ZONE 8

ZONE 1

ZONE 2

RJ45 Zone

 

 

 

 

ports

Figure 2.5: MRKP1E Keypad Installation

MRKP1E REAR

MRKP1E REAR

MRKP1E REAR

MRKP1E REAR

MRKP1E REAR

MRKP1E REAR

Figure 3.0: MRKP1E to MRC88m with expansion keypads

Note: Four keypads maximum per zone. Remove termination jumper on all keypads except for the last keypad (see item #4 on Fig 2.3). Each expansion keypad must each have its own unique address. (see Inst. Setup Menu on Section 4 of this manual)

11

 

 

 

12

 

 

Image 12
Contents Installation Instructions Safety Information Xantech Limited WarrantyCaring For the MRKP1E Clean only with a dry soft cloth Operating Temperatures & EnvironmentsPrecautions Specifications Extending external IR receiver connection with 3-wire cableTroubleshooting IntroductionDefining Terms Zone Local Source / SourceRetro-Fit Wiring/ Post Construction System Design Overview/ApplicationsPlanning Pre-ConstructionPre-Wiring CAT-5 Wiring between MRC88m and MRKP1E User Setup ParametersInst Setup Parameters MRKP1E Main Setup Menu MRKP1E Front PanelDescription MRKP1E Rear Connectors Item DescriptionExternal IR Receiver Connections Installation Internal IR ReceiverCompatible Handheld remotes Connections MRKP1E to MRC88m and Expansion Keypads