6. Specifications

MRKP1E basic dimensions and cable lengths

Front panel dimensions

80mm height x 83.8 width x 15.3mm thick

3.15” height x 3.3” width x 0.6” thick

 

 

 

 

 

Wall Hole size

69mm (2.7”) diameter hole when using

compatible EU back box.

 

Unit Depth in-wall

43.2mm (1.7”) depth when using compatible

EU back box

 

Max length Cat-5 Cable

152 meters (500 feet) total per zone

with 1 keypad

 

 

 

 

 

 

 

Max length Cat-5 cable

77 meters (250 feet) total per zone

with 1 keypad and 1

expansion keypad

 

 

 

 

 

 

 

Max length Cat-5 cable

38 meters (125 feet) total per zone

with 1 keypad and 3

expansion keypads

 

 

 

 

 

 

 

Operating

Operating Temperature: 32-104°F (0-40° C)

Temperatures &

Humidity: 0-90%

Environments

 

 

 

 

 

 

 

 

 

 

 

Compatible Electrical back-boxes

 

 

 

 

EU back-box

Legrand® 801 01, EAN 3 245060 905019

(40mm Depth x 60mm Inner Diam.)

 

 

 

 

 

UK back-box

Standard UK one-gang 47mm depth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Extending external IR receiver connection with 3-wire cable

Size (AWG)

Maximum allowable

length (feet)

 

24

150

 

22

300

 

20

1000

 

18

2000

 

 

 

 

 

 

 

Extending external IR receiver connection

with Cat-5 cable using all 8

conductors

Use 4 striped wires for GND

Use 2 solid wires for IR signal

Use 2 solid wires for +12V

3

 

 

 

20

 

 

Image 4
Contents Installation Instructions Safety Information Xantech Limited WarrantyOperating Temperatures & Environments Caring For the MRKP1E Clean only with a dry soft clothPrecautions Specifications Extending external IR receiver connection with 3-wire cableTroubleshooting IntroductionDefining Terms Zone Local Source / SourceRetro-Fit Wiring/ Post Construction System Design Overview/ApplicationsPlanning Pre-ConstructionUser Setup Parameters Pre-Wiring CAT-5 Wiring between MRC88m and MRKP1EInst Setup Parameters MRKP1E Front Panel MRKP1E Main Setup MenuDescription Item Description MRKP1E Rear ConnectorsExternal IR Receiver Connections Internal IR Receiver InstallationCompatible Handheld remotes Connections MRKP1E to MRC88m and Expansion Keypads