The CC62 should normally be plugged into an unswitched AC outlet. However, if the power to the CC62 is interrupted by a power failure or other reason, the internal memory will retain the last selected switched condition for each of the relays.
IR RCVR INPUT CONNECTOR
This
A special jumper, inside the CC62, gives you the option to make the grounds common or have them isolated. Refer to Fig. 3.
To gain access to this jumper, remove the eight screws that secure the top cover to the metal chassis. Carefully lift the cover
Jumper ON Position. (Common ground between GND and GND terminals - factory default setting)
JP1 |
LED1
PCB
Metal Chassis
JP1
LED1
PCB
off. When you have made the adjustment, reassemble in reverse order.
NOTE: When shipped from the factory, the jumper is installed in the ON (common) position.
Jumper OFF Position (Isolated Grounds).
No connection between the GND and GND terminals.
Fig. 3 Location and Adjustment of Grounding Jumper
CAUTION: When powering IR receivers and keypads directly from the CC62, you must leave the jumper installed in the ON position so that the two G terminals are connected in common. This provides the needed ground return for the IR signal.
Change the jumper to the OFF position only when powering IR source devices separately from the CC62 and there is a need for electrical isolation.
INSTALLATION
Typical applications for the CC62 are as follows:
•To activate shade or drape pulls, projector lifts, screen drops, etc. Use Momentary On modes at relay #1 to close and at relay # 2 to open, if such devices require two separate dry contacts to operate.
•To switch low voltage lighting or other devices: Use Toggle or the ON & OFF (pair) commands. Pair commands allow a known ON/OFF status from remote rooms where visual status is not possible.
•Amplifier A/B switching: Each relay can be connected so that a stereo pair of speakers (in each remote room) can be switched between two AV receivers. This effectively creates a simple
Each remote control and keypad used in the system needs to be programmed with Toggle or Pair commands from the RC68+ to do the A/B switching. In addition, each room needs a dedicated learning remote or keypad having the RC68+ IR commands that operate the specific CC62 relay for each room.
NOTE: The CC62 is shown connected to Xantech
•Another important application of the CC62 is to provide
Up to 16 independent closures are possible by using as many as three CC62's with a
|
|
|
|
|
| |