MZ-NF610
•Adjustment Method of VREC_LOW (X2 speed) (item number: 751)
Set LCD display
•Adjustment Method of VREC_HIGH (HEAD MOTOR) (item number: 753)
Set LCD display
7 51 | AD ** |
|
|
**: Adjusted value |
|
1.Connect a digital voltmeter to the TP1620 (VREC) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
TP1620 (VREC)
TP1311 (GND)
2.Press the X key on the set or the key on the remote commander to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
•Adjustment Method of VREC_MIDDLE (X4 speed) (item number: 752)
Set LCD display
7 52 | AD ** |
**: Adjusted value |
|
1.Connect a digital voltmeter to the TP1620 (VREC) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
TP1620 (VREC)
TP1311 (GND)
2.Press the X key on the set or the key on the remote commander to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
7 53 | AD ** |
|
|
**: Adjusted value |
|
1.Connect a digital voltmeter to the TP1620 (VREC) on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
TP1620 (VREC)
TP1311 (GND)
2.Press the X key on the set or the key on the remote commander to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
•Adjustment Method of CHGV_LOW (item number: 755)
Set LCD display
7 55 | AD ** |
|
|
**: Adjusted value |
|
Note: Remove the rechargeable battery.
1.Connect a digital voltmeter to the BATT+ and BATT– on the MAIN board, and adjust [VOL +] key (voltage up) or [VOL
digital voltmeter
MAIN board
BATT +
BATT –
2.Press the X key on the set or the key on the remote commander to write the adjusted value.
Adjustment and Connection Location: MAIN board (see page 24)
22