AG Neovo ATP/AST Series Reliability Condition, Recommended Connector, Temperature Condition

Page 7

ATP/AST Series Product Specifications

3. Reliability Condition

3-1. Temperature Condition

§Temperature Condition Test

Following test are performed in the condition with no dew condensation:

Cold Test:

Tested after leaving the parts in -30°C±3°C for 240 hours and in the room temperature

 

for 2 hours.

Heat Test:

Tested after leaving the parts in 80°C±3°C for 240 hours and in the room temperature for

 

2 hours.

Humidity Test: Tested after leaving the parts in the temperature 60°C±3°C, humidity 90 to 95% for 240

 

hours and in the room temperature for 2 hours.

Cycle Test:

Tested after 5 cycles of leaving the parts in the temperature -30°C±3°C for 1 hour and in

 

the room temperature for 0.5 hours, then leaving the parts in the temperature 70°C±3°C

 

for 1 hour and in the room temperature for 0.5 hours.

Judgement:

Must satisfy the following:

 

Activation Force:

Within ±50% of the specification.

 

Linearity:

Must satisfy the specification.

 

Terminal Resistance:

Must satisfy the specification.

 

Insulation Resistance:

Must satisfy the specification.

 

Appearance:

Must satisfy the specification.

4. Recommended Connector

4-1. Recommended Connector

Part No.

Pins

Pitch

 

 

 

KCA-K4R

4 pin Double-sided

1.25mm

 

 

 

7

Rev. 10©1999 - 2006 DMC Co., Ltd.

Image 7
Contents Page Table of Contents Product Specifications Width mm Length mm Acceptable Numbers ATP/AST Series Product Specifications AppearanceTesting Regulation Testing Regulation§ Terminal Resistance Test Condition Reliability Condition Recommended ConnectorTemperature Condition Recommended ConnectorConstruction Notes PrecautionsHandling Notes Handling NotesATP/AST Series Product Specifications Mounting Notes Warranty Revision history ATP/AST Series Product Specifications ATP/AST Series Product Specifications