Hearth and Home Technologies SMART-STAT-II Setting 0F/0C Scale, Setting the Countdown Timer

Page 5

Figure 6. Setting Button/Child Proof Lockout

Setting 0F/0C Scale

The factory setting for temperature is degrees Fahrenheit (0F). To change this setting to degrees Centigrade (0C):

1.Remove the battery cover on the back of the trans- mitter and locate the “setting button” at the top cen- ter of battery compartment (see Figure 6).

2.Push setting button and 0F will begin flashing on the LCD screen (see Figure 5, Location #4).

3.Push the DOWN button on the transmitter to change 0F to 0C.

4.Push “setting button” on transmitter and Centigrade (0C) degree readings will display on LCD screen.

5.Repeat this process to change back to Fahrenheit (0F) reading, this time pushing the UP button. NOTE: LCD screen will return to normal state if set- ting button is not pushed within 15 seconds.

Setting Desired Room Temperature -

Thermo Operations

This remote control system can be thermostatically controlled when the transmitter is in the THERMO mode. (THERMO must be displayed on the screen). The trans- mitter will “sense” the room temperature every two min- utes automatically turning the fireplace ON or OFF ther- mostatically. To set the desired room temperature:

1.Press the MODE button to place the transmitter into THERMO mode. THERMO ON or OFF will dis- play.

2.Press the UP or DOWN button to select the desired room temperature. The highest SET temperature is 990 F (370 C). The lowest SET temperature is 450 F (70 C).

NOTE: To prevent repeated thermo-cycling of the gas appliance, the sensing unit in the transmitter will only activate the remote receiver when the temperature change exceeds 10 F (1/20 C) above or below the SET (desired) temperature.

When the transmitter is in the THERMO mode, it should be kept away from direct sources of heat such as fire- places, incandescent lighting and direct sunlight. Leav- ing the transmitter in direct sunlight, for example, will cause it to read the room temperature higher than it actually is.

Setting the Countdown Timer

This remote control system can operate with a built-in countdown timer when the transmitter is in the ON or THERMO modes (THERMO or ON must be displayed on the LCD screen).

1.Press and release the TIMER/TIME button on the transmitter. The word TIMER and 0:15 flash on the screen (see Figure 5, Location #2).

2.Press the UP and DOWN button to begin advancing through each of the countdown time options. Avail- able countdown times are 15 min, 30 min, 45 min, 1 hour, 1 hr 30 min, and each additional half hour up to nine hours.

3.To set the TIMER, press the SET button on the trans- mitter. If the system is ON, it will remain on until the “time” has expired. If the system is in the THERMO mode, it will cycle on and off as the room tempera- ture requires until the “time” has expired.

NOTE: When the timer is used in the THERMO mode, the THERMO operation will discontinue when the “time” has expired.

Low/Battery Indicator

An “X” outlined by a battery on the right side of the LCD screen will appear when battery power has dropped significantly. At this time, approximately two weeks of battery power remains.

5

Image 5
Contents Canadian Equipment Requirements Installation PrecautionsIntroduction FCC Requirements Remote Receiver Installation InstructionsReceiver Wiring Instructions Transmitter Wiring Electronic Spark IgnitionsSetting the Clock Transmitter SettingsMatching Security Codes Operating InstructionsSetting Desired Room Temperature Thermo Operations Setting 0F/0C ScaleSetting the Countdown Timer Low/Battery IndicatorSystem Check Transmitter Safety FeaturesGeneral Information Standing Pilot Ignition Wiring Diagram Intermittent Pilot Ignition IPI Wiring DiagramWHT ORG Valve Remote Control Wiring Diagrams