Delfield 536-SR68 & 536-SRR68 Installation, Operation Information, Display Case Glass Replacement

Page 3

Installation

Location

These units are intended for indoor use only. Be sure the location chosen has a floor strong enough to support 1000 pounds of the cabinet and contents. Reinforce the floor as necessary to provide for maximum loading.

For the most efficient refrigeration, be sure to provide good air circulation inside and out.

Inside cabinet: Do not pack refrigerator so full that air cannot circulate.

Outside cabinet: Be sure that the unit has access to ample air. Avoid hot corners and locations near stoves and ovens.

Leveling

A level cabinet looks better and will perform better because:

1.The drain pan will drain properly.

2.The doors will line up with the frames properly.

3.The cabinet will not be subject to undue strain.

To meet NSF standards, this unit must be sealed to the floor.

Installation of glass shelves

1.Remove stainless steel shelf bracket assemblies by sliding key slots over shoulder bolts on inside edges of posts.

2.Plug light cords into receptacles.

3.Place 0.25” safety glass shelves on brackets.

Installation of dry section front & side glass

1.Remove (2) acorn nuts on bottom side of shelf.

2.Remove top of stainless steel shelf by lifting shelf off subtop.

3.Place 0.25” thick side glass pieces into bottom channel and lower rear of stainless steel shelf.

4.Place 0.25” thick front glass piece into bottom channel and lower front of stainless steel shelf over top edge of glass.

5.Replace acorn nuts on bottom side of shelf.

Dual View Series Service and Installation Manual

Plumbing

Self-contained models are standard with a condensate evaporator. If the evaporator fails, the unit’s drain must have an outlet to an appropriate drainage area or container.

Moisture collecting from improper drainage can create a slippery surface on the floor

CAUTION and a hazard to employees. It is the owner’s responsibility to provide a container or outlet for drainage.

Electrical connection

Refer to the wattage data on page 2, the serial tag and your local code to be sure the unit is connected to the proper power source. A protected circuit of the correct voltage and amperage must run for connection of the line cord, or permanent connection to the unit.

Self-contained units have an ON/OFF switch located in the base of the unit. Simply turn the switch to ON to begin operation.

The power switch must be turned OFF and the unit disconnected from the power source whenever performing service or maintenance functions.

Operation Information

On self-contained models, after turning the ON/OFF switch to ON, the unit’s compressor will begin operating. Delfield display cases are designed to maintain an operation temperature of 36°F to 40°F at ambient room temperature of 75°F and relative humidity of 55%.

Do not load the storage area in a way that restricts the air flow. Overloading will result in a loss of temperature.

Continuous opening and closing of the doors will hamper the units ability to maintain operational temperature.

Display Case Glass Replacement

Delfield professionally packages the glass in the crate to minimize the risk of freight damage. However, during shipment glass damage can happen and breakage is not covered under warranty. If your Delfield unit arrives with broken glass in the top dry section, we recommend that you purchase replacement glass locally. The table to the right lists replacement sizes for the dry top section only.

Shelves

(Top)

34.0” x 15.84”

(Center)

34.0” x 17.24”

(Bottom)

32.50” x 15.43”

Front

24.95” x 35.0”

Sides

Two Each Required:

24.57” tall;

19.38” at bottom

15.04” at top

Please call your Delfield service or sales representative if you have any questions on glass replacement.

*** All glass shelving is .25” thick safety glass.***

Delfield®

For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com

 

Image 3
Contents Delfield Receiving And Inspecting The Equipment ContentsSpecifications Serial Number LocationInstallation Display Case Glass ReplacementOperation Information Door Gasket Maintenance MaintenancePressure Control Settings Display Case Condensation And Temperature AdjustmentWiring Diagram Description Part# Replacement PartsLabor of 2 Hours to Replace Standard One Year Warranty One year parts, 90 days labor Delfield Model# Serial # Date Delfield Delfield Thank you for choosing Delfield

536-SR68 & 536-SRR68 specifications

The Delfield 536-SR68 and 536-SRR68 are two innovative refrigeration solutions designed to meet the demands of commercial kitchens and food service environments. With a focus on efficiency, durability, and user convenience, these models are ideal for establishments that require reliable storage for perishable goods.

One of the standout features of both the 536-SR68 and 536-SRR68 is their exceptional cooling performance. Equipped with a powerful refrigeration system, these units are capable of maintaining consistent temperatures, ensuring that food items remain fresh and safe. The temperature range typically spans from 33°F to 41°F, providing optimal conditions for storing a variety of perishable products.

The design of the Delfield models emphasizes energy efficiency. They are built with high-density, foamed-in-place insulation, which minimizes energy loss and helps maintain internal temperatures. This not only reduces operational costs but also aligns with energy conservation efforts within commercial kitchens.

The construction of the 536-SR68 and 536-SRR68 is another remarkable aspect. These refrigeration units feature stainless steel exteriors that are durable and easy to maintain. The interiors are also designed for hygiene, featuring a smooth, rounded corner design that facilitates effortless cleaning and minimizes food debris accumulation.

In terms of capacity, the 536-SR68 and 536-SRR68 offer ample storage space, accommodating a significant number of food items. The shelves are adjustable, allowing users to configure the interior to suit their specific needs. This flexibility is crucial for busy food service environments where quick access to ingredients is essential.

Both models incorporate advanced technologies that enhance usability. Digital controls offer precise temperature adjustments, and some variants feature monitoring systems that alert users to any fluctuations in temperature. This proactive approach to temperature management helps maintain product quality and reduces waste.

The Delfield 536-SR68 and 536-SRR68 are designed with accessibility in mind. They include user-friendly features such as self-closing doors, which increase convenience while preventing accidental temperature rises. Moreover, the doors are equipped with magnetic gaskets that provide a secure seal and help maintain efficiency.

In conclusion, the Delfield 536-SR68 and 536-SRR68 stand out as reliable, high-performance refrigeration units tailored for the demands of commercial kitchens. Their robust construction, energy-efficient technologies, and user-centric features make them invaluable assets for any food service operation looking to optimize food storage and ensure food safety.