Recording
7.2 ALARM RECORDING
During user setting “ON” in the ALARM OPERATION, The image will automatically record when alarm occurs , and will automatically stops recording at the end of the alarm duration period.
As example, we set ALARM RECORDING SPEED on 60 IPS, and the ALARM DURATION TIME is 5 seconds, the screen will show as below,
A.REC (60 IPS)
DISK: 39 GB (0)
Instant recording and timer recording will stop when an alarm occurs.
|
|
|
|
| Press MENU key and turn the jog dial to select the ALARM | |
|
|
|
|
| ||
|
|
|
|
| RECORDING SETTING MENU. | |
MENU | ||||||
|
RECORDING OPERATION:
ON: Enables alarm recording,
OFF :Disables alarm recording.
RECORDING SPEED:
Set the recording speed when alarm occurs.
RECORDING QUALITY:
In alarm duration, the recording quality can be set which is different from instant or timer recording.
ALARM – 1 TYPE
ALARM – 2 TYPE
ALARM – 3 TYPE
ALARM – 4 TYPE
Select the separate type of ALARM 1 to ALARM 4 TYPE input to be Normal Close (N.C.) or Normal Open (N.O.)
34