American Dynamics ADNSNVR-CL1 specifications Bundled Server Mechanical Specifications

Page 18

Architect & Engineer Specification

AMERICAN DYNAMICS

 

 

VIDEOEDGETM NETWORK VIDEO RECORDER

optical drive. The bays must be behind a locking front cover that restricts access not only to the drives, but also to the power switch and reset switch.

83.The Network Video Recorder shall be the American Dynamics VideoEdge® Series or equivalent.

2.03BUNDLED SERVER MECHANICAL SPECIFICATIONS

Unit Dimensions (HxWxD)

8.64 cm

(3.4”)

High with Bezel

 

44.43 cm

(17.5”)

Wide

 

74.40 cm

(29.31”)

Deep

Rack Height

Two units (2U)

Rack-mountable

 

 

chassis

 

Unit Weight

23 kg.

(50.71 lbs.) Maximum

 

 

 

configuration

2.04BUNDLED SERVER ELECTRICAL POWER REQUIREMENTS

Input

Redundant 750W Hot-Plug Auto-Switching

 

100-220 VAC, 50/60 Hz

2.05BUNDLED SERVER ENVIRONMENTAL CONDITIONS

Operating Temperature

10° to 35° C (50° to 95° F)

 

Storage Temperature

-40° to 65° C (-40° to 149° F)

 

Operating Relative Humidity

20% to 80% non-condensing (twmax=29C)

Storage Relative Humidity

5% to 95% non-condensing (twmax=38C)

Operating Vibration

0.26G at 5Hz to 350Hz for 2 minutes

 

Storage Vibration

1.54Grms Random Vibration at 10Hz to 250Hz

 

 

for 15 minutes

 

Operating Shock

1 shock pulse of 41G for up to 2ms

 

Storage Shock

6 shock pulses of 71G for up to 2ms

 

Operating Altitude

-16m to 3,048m (-50ft to 10,000 ft)

 

Storage Altitude

-16m to 10,600m (-50ft to 35,000 ft)

 

Emissions

FCC (U.S. only) Class B

 

 

 

ICES (Canada) Class B

 

 

 

CE Mark (EN 55022 Class B, EN55024,

 

 

EN61000-3-2, EN61000-3-3)

 

 

 

VCCI (Japan) Class B

 

 

 

BSMI (Taiwan) Class A

 

 

 

C-Tick (Australia/New Zealand) Class B

 

8200-2608-01 B0

VideoEdge® Network Video Recorder

18 of 20

Image 18
Contents References Part 1 GeneralSummary DefinitionsAmerican Dynamics System DescriptionSubmittals Quality Assurance DELIVERY, STORAGE, and HandlingProject Conditions WarrantyMaintenance SequencingManufactured Units TrainingPart 2 Products System PerformanceAmerican Dynamics American Dynamics American Dynamics American Dynamics American Dynamics American Dynamics American Dynamics American Dynamics American Dynamics American Dynamics American Dynamics American Dynamics Bundled Server Mechanical Specifications Bundled Server Electrical Power RequirementsBundled Server Environmental Conditions Examination InstallationPart 3 Execution PreparationTesting and Certification