10.SPECIFICATIONS Electrical
Model | Rated | Voltage | Power at |
No. | Voltage | Range | Min.Voltage |
RT30A/50 | 230 Vac, 50 Hz | 90 to 264 | 22 W |
RT960A/50 | 230 Vac, 50 Hz | 90 to 264 | 22 W |
RT30A/60 | 120 Vac, 60 Hz | 90 to 264 | 22 W |
RT960A/60 | 120 Vac, 60 Hz | 90 to 264 | 22 W |
Tape Format: Standard 12.7 mm (0.5 inch) VHS tape.
Video Recording System: VHS
Rotary Heads: Four head helical scan azimuth system.
Luminance: FM recording.
Color: Converted subcarrier, direct recording.
Selectable Speeds (Recording & playback): RT30A/50: 6, 18, and 30 hours on
960 hours on
RT30A/60: 6, 18, and 30 hours on
RT960A/60: 6, 18, 30, 72, 96, 120, 168, 240, 480, and 960 hours on
Alarm Record Speeds:
RT30A/50 & RT960A/50: 6, 18, and 30 hours mode.
RT30A/60 & RT960A/60: 6, 18, and 30 hours mode.
High Speed Video Scan:
RT30A/50 & RT960A/50: 9 x
RT30A/60 & RT960A/60: 9 x
Rewind/Fast Forward Time: Less than 70 seconds
Alarm Command:
From the Recording or Ready Mode:
Turns on Alarm Indicator and
during later visual search.
The selected alarm recording speed can be programmed to continue for a period of 30 seconds, 1, 3, 5, 10 minutes or until tape end.
Typical Delay Time Before Alarm Recording: From STOP Mode:Approx. 3 sec.
From RECORD Mode: Less than 1 sec.
Video:
RT30A/50 & RT960A/50: PAL color/ CCIR monochrome.
RT30A/60 & RT960A/60: NTSC color/EIA monochrome.
Input: 1.0
Output: 1.0
Monochrome: 320TV lines.
Color: 270 TV lines.
Audio:
Audio Recording possible in 6, 18, 30 hours mode Input:
Output:
Time/Memory Power-Loss Backup: 2 weeks
Indicators:
Alarm
Series
Record
Timer
Cassette
Index
Power failure
Key lock
Repeat
Function (clock, tapecounter, error)
VCR function
Controls:
Power
Record
Joggle Shuttle
Play
Stop/Eject
Still
Clear
Clock
Menu
Key lock
Tracking
Connectors:
VIDEO IN: 1; BNC.
VIDEO OUT: 1; BNC.
AUDIO IN: RCA Phono jack.
AUDIO OUT: RCA Phono jack.
EXTERNAL INTERFACE*:
*Alarm In/Out; Series In/Out;VEXT;Tape End Out;
Mechanical
Finish: Gray
Dimensions (w x d x h) : 360 x 270 x 94 mm (14.2” x 10.6” x 3.7”)
Weight: Approximately 3.8 kg (8.4lbs)
Environmental
Temperature: +5 ºC to +40 ºC (+41 °F to +105 ºF).
Humidity: Less than 80% RH
Electromagnetic Compatibility
EMC Requirements:
50 Hz Models: 89/336/EEC. Immunity:
Voltage Fluctuations:
60 Hz Models: U.S.A. and Canada. FCC Part 15, Class B.
Safety:
50 Hz Models: CE.
LVD Requirements: 73/23/EEC; EN60065.
60 Hz Models: UL & cUL.
UL: UL 1492.
CSA: CSA 22.2, No.1.