Lumex Syatems FR587WH operating instructions Heat and Massage Unit Setup Instructions

Page 15

2.The control module, the brains of the system, is inside the junction box. Both are shown at right.

3.The power supply, which has an 8-foot power cord that plugs into the wall power outlet, is shown at right.

Control Module (Junction

Junction Box

Power

Box Cover Removed)

 

Supply

Heat and Massage Unit Setup Instructions

. CAUTION:.To.prevent.personal.injury.and.damage.to.the.recliner. always.obtain.assistance.when.positioning.the.recliner.as. instructed.in.the.following.sections.

1.Install the back assembly and gas spring on the seat frame with the clevis pins and clips supplied with the recliner as indicated previously in the recliner Assembly and Operating Manual.

2.Remove the left side table (on the side opposite the mounted switch box) from the recliner to prevent damage to it during setup: Withdraw the ball lock pin, shown at right, and set ball lock pin and table aside.

3.Place a protective cover or drop cloth on your workbench or floor to protect the recliner frame finish and upholstery. With assistance, carefully roll the recliner and rest it on its left side to provide access to the seat bottom, as shown at right. If desired, for better access, you may roll the recliner completely upside down. Carefully extend the footrest partway for access to the components, as shown at right.

. WARNING:.DO.NOT.place.your.hands.in.the.path.of.the.moving. recliner.mechanism..Moving.parts.could.cause.personal.injury.

4.Use a 1/4" hex wrench to remove the two hex head screws that secure the junction box cover (see picture of junction box at top of page). Remove the junction box cover to expose the control module.

5.Insert the cable connector labeled SWITCH through the bushing in the plastic skirt at the bottom of the back cushion as shown at right.

6.Insert the cable connector labeled SWITCH into the control module connector also labeled SWITCH (see picture of control module at top of page) until its locking tab snaps into place.

7.See picture at right. Use Phillips screwdriver to remove the screw that secures the cushioned cable clamp. Remove the clamp and place it around the switch box cable. Slide the clamp over the cable until the holes in the clamp tabs are in line with the screw, then pinch them closed. Insert the screw through the clamp tabs, then reinstall the screw and tighten it with a Phillips screwdriver.

8.Route the cables from the back cushion between the rear seat frame crossbar and seat bottom.

ball lock

left

pin

side table

Remove

Left Side Table

Roll Recliner

onto its Left Side

Insert Cable

Connector Labeled

SWITCH

Through Bushing

switch box cable clamp tabs

screw clamp

Secure Switch Box

Cable Clamp

FR587W-INS-LAB-RevC13: Deluxe Extra-Wide Clinical Care Recliner Assembly and Operating Instructions

15

Image 15
Contents Save this Manual for Future USE Contents Important Safety PRECAUTIONS-PLEASE Read Before USE IntroductionIntended USE Distributed Product Description AssemblyUpholstered Back Assembly UnpackingBack as shown at right Place Clevis Pins Place Cotter Pins Tente Casters OperationTo lower table Lift the side table up slightly until tabs Side Table OperationSide Panel Operation Third Position Second Recline Position Recliner OperationFirst Position Upright Position Second Position First Recline PositionBack Angle Adjustment Trendelenburg Position Also Known as Shock PositionTrendelenburg Position can be obtained from any position Adjusting Cable Tension GAS Spring Troubleshooting GuideConnection Lumex Clinical Care Recliners with Heat and Massage FeatureInstallation and Operating Guide DescriptionHeat and Massage Unit Setup Instructions Heat and Massage Unit Operation Instructions Heat and Massage Unit Troubleshooting Guide POST-INSPECTION Care and Maintenance Upholstery Maintenance and Stain RemovalEvery Three Months Page Page Technical Specifications Limited Warranty