MS20H/MS20E MIXER — ELECTRIC MOTOR
Electric Motor
For maintenance care and operation of the electric motor, refer to your electric motor instruction booklet furnished with the motor.
Protect the electric motor from dust as much as possible and keep ventilating openings clean.
CAUTION:
■DO NOT spray water at any time on the electric motor.
■DO NOT operate electric motor in a explosive environment.
The electric motor used in this mixer is a
Electric Motor Connection
A 12 inch electrical cable (Figure 2) with a pigtail at one end is provided with the electrical motor for hookup to a power source. Table 1. shows the required NEMA connector for the desired motor horsepower rating. In addition, Table 2 also shows the matching NEMA approved connector for the required extension cord.
ALWAYS, make certain that the power source required for the electric motor is correct and always use the correct NEMA configuration plug. Failure to supply the correct voltage to the motor can severely damage the motor.
The motor supplied is wired for 115 VAC grounded operation. Make certain that the correct size grounded
Motors can burn out when the line voltage falls 10% below the voltage rating of the motor. Failure to use proper voltage will cause the motor to overheat and actuate the overload switch.
If overload protection should actuate because of improper voltage or any other malfunction, turn the main switch on the motor to the "OFF" position and correct the problem, press the reset switch button, and turn the main switch to the "ON" position.
It is strongly recommended that all electrical wiring be done by a licensed
NOTE electrician. Special attention should be given to the electric switch as well as the
set forth in the local electrical safety code handbook.
Electric MotorVoltage Switch
1.ALWAYS make certain the motor switch is "OFF" and the power cord has been disconnected from the power source.
2.Remove the voltage
3.Replace the voltage
4.Important!, when changing the input voltage to the motor from 115 to 230 VAC the plug on the motor power cord must also be changed. See Table 3.
Table 3. Electric Motor Wiring Information
Motor |
| ||
Horsepower |
|
| |
NEMA Plug Connector | Mating NEMA | ||
Rating | |||
| Receptacle Connector | ||
|
| ||
|
|
| |
1.5 HP | |||
(115 VAC) | |||
|
| ||
|
|
| |
1.5 HP | |||
(230 VAC) | |||
|
| ||
|
|
|
Table 4. Recommended Extension Cord Sizes
Model | Motor | Voltage | 50 ft. | 75 ft. | 100 ft. | 200 ft. | |
(15.24 m) | (22.86 m) | (30.48 m) | (60.96 m) | ||||
|
|
|
|
|
|
| |
MS20E | 1.5 HP | 115 | No. 12 | No. 10 | No. 8 | No. 6 | |
|
|
|
|
| |||
(Electric) |
|
|
|
|
| ||
230 | No. 14 | No. 12 | No. 12 | No. 8 | |||
|
| ||||||
|
|
|
|
|
|
|
MQ STOW MS20H/MS20E MIXER — PARTS & OPERATION MANUAL — REV. #3 (08/10/06) — PAGE 15