Lamp Installation
When replacing the lamp, please wait 15 minutes after powering down to allow the unit to cool down! Always disconnect from main power prior to lamp replacement.
Do not touch the envelope (glass area) of the bulb with bare hands. If this happens, clean the lamp with alcohol and wipe it with a lint free cloth before installation.
| Unscrew grounding wire | Unscrew and release |
| lamp wires from the main | |
| from PCB. | |
| PCB. | |
|
| |
|
| Remove the 4 corner |
| screws to allow the | |
|
| temporary removal of the |
|
| safety glass cover. |
Lamp is removed and replaced through the front of the fixture. You must first remove the glass cover. Attempt to remove the lamp after you have released all wire leads from the PCB. Push back on both spring terminal ends inside the lamp reflector to release the linear lamp from the grip of both spring terminals and pull lamp outwards as you apply the pressure. Repeat procedure to replace and reconnect wire leads to the appropriate terminals on the PCB. Make sure wires are tightly screwed onto the PCB.
10 |