LED Indicators
6 Gbps SAS I/O module | 14 |
| the three SAS ports, and two for the module status |
Fan module | • One |
| status |
| • One |
| status (not currently used) |
| • One |
| status |
| • One |
| status |
PSU | • One single‐color LED indicator for PSU fault |
| status |
| • One single‐color LED indicator for AC fault |
| status |
| • One single‐color LED indicator for power status |
|
|
Power Supply Units (per PSU) |
|
|
|
Watt | 2.8 kW |
Voltage | |
Heat dissipation | |
Maximum inrush current | Under typical line conditions and over the entire |
| system ambient operating range, the inrush current |
| may reach 55 A for each PSU for 10 ms or less. |
|
|
Available Hard Drive Power (Per Slot) |
|
|
|
Supported hard drive power consumption | Up to 1.16 A at +5 V, Up to 1.6 A at +12 V |
(continuous) |
|
|
|
I/O Card Power (Per Slot) |
|
|
|
Maximum power consumed by I/O Card | 11 W at +12 V |
Maximum available power | 100 W at +12 V |
Maximum available power | 1 W at +5 V (standby) |
|
|
Physical |
|
|
|
Height | 22.23 cm (8.75 inches) |
Width | 48.26 cm (19 inches) |
28