Dell MD1280 manual Front-panel features and indicators

Page 6

Figure 1. Front-panel features and indicators

Table 1. Front-panel features and indicators

Item

Name

Panel

Description

 

 

 

 

1

Enclosure status indicator

 

• Unit ID Display: Displays the enclosure

 

 

 

unit identification number. The unit

 

 

 

identification number is helpful when

 

 

 

setting up and maintaining a multiple

 

 

 

enclosure configuration.

 

 

 

• Input Switch: Not used.

 

 

 

• Power On/Standby:

 

 

 

– Off — The enclosure power is

 

 

 

turned off

 

 

 

– Green — The enclosure is ‘On’

 

 

 

(operational)

 

 

 

– Amber — The enclosure is in

 

 

 

standby (not operational) mode.

 

 

 

• Module Fault: Amber when there is a

 

 

 

hardware fault. Also, an LED may glow

 

 

 

on a PSU, hard drive, DDIC, fan module,

 

 

 

or EMM indicating a faulty device.

 

 

 

• Logical Status: Amber when there is a

 

 

 

change of status or when devices other

 

 

 

than the enclosure fails.

 

 

 

• Drive drawer 1 Fault: Amber when a

 

 

 

hard drive, cable, or sideplane fails in

 

 

 

drive drawer 1.

6

Image 6
Contents Dell Storage MD1280 Service Guide Page Contents Technical specifications Contacting Dell Dell Storage MD1280 overview About the Dell Storage MD1280 Service GuideFront-panel features and indicators Dell Storage MD1280 hardwareFront-panel features and indicators Back-panel features and indicators EMM features and indicators Back-panel features and indicatorsFan module features and indicators O EMM features and indicatorsPSU features and indicators Fan module features and indicatorsDdic indicator Ddic indicatorDdic indicator General safety precautions Safety precautionsElectrical safety precautions Replacing Dell Storage MD1280 componentsPre-replacement tasks Replacing PSUsRemoving a PSU Replacing fan modules Identifying the failed fan moduleReplacing a fan module Replacing hard drives Numbering the hard driveIdentifying the failed hard drive Replacing hard drivesOpening a Ddic Ddic Replacing I/O EMM modules Closing a drive drawerIdentifying the failed EMM Replacing an EMMReplacing chassis Replacing rack railsPost-replacement tasks Turning on the EMMs and enclosureTroubleshooting PSUs Troubleshooting Dell Storage MD1280 componentsTroubleshooting fan modules Troubleshooting DDICsTroubleshooting I/O EMMs Technical specifications PSU Physical Depth front mounting bracket to rear surface Page Page Contacting Dell