Perlick NS Series, NR Series warranty General Information Narrow Door Back Bar Cabinets

Page 2

General Information – Narrow Door Back Bar Cabinets

Parts List

(3) Shelves per door (one may be used as a floor rack)

Door lock keys

Shelf clips

Tools Required

#2 Phillips Screwdriver

3/8” Nut Driver

Power Drill or Driver (for leg or caster installation)

Plumbing

Condensate from the cooling coil is automatically evaporated from the condensate pan located in the condensing unit housing. Each unit is also equipped with a floor drain located in the right rear corner of the cabinet. The drain can be plumbed to an external floor drain by connecting to the 3/4” NPT thread out the side or the 1” NPS thread out the bottom. Both drains ports come plugged from the factory and can be removed if needed.

NOTE: Remote units require evaporator condensate to be plumbed to an external drain.

Electrical

The cabinet must be connected to a separately fused power source (see electrical specification plate) and grounded in accordance with National and Local Electrical Codes. Caution: Do not attempt to operate the equipment on any other power source than that listed on the Electrical Specification plate.

Uncrating and Inspection

Remove all crating material before operating. Carefully inspect cabinet for hidden damage. If damage is discovered, file your claim immediately with the transportation company. Perlick is not responsible for damage in transit.

Placing the Cabinet

Push the cabinet into place using rollers when necessary. IMPORTANT: Proper air flow around the condensing unit is necessary for efficient operation. Never obstruct the air flow in and out of the condensing unit.

For sanitation purposes, it may be necessary to seal the base of the cabinet to the floor. This can be accomplished by laying a bead of silicone sealant between the base of the cabinet and the floor as shown by the figure below:

Leveling the Cabinet

When the cabinet is in place, check installation with carpenter’s level. When level front to back and left to right, accumulated water will drain out of the cabinet.

Installing Casters or Legs (optional)

Attach casters or legs to cabinet bottom in holes provided. Use the supplied 1/4”-20 x 3/4” hex head self-tapping machine screws.

Installing Base Plates (optional)

Attach brackets to cabinet bottom in holes provided. Attach base plate to brackets (see separate instructions, provided with kit). When returning cabinet to upright position, be careful not to bend brackets.

WARNING! To avoid compressor damage, after running cabinet in an upright position, let unit stand for 24 hours before plugging in and running the unit.

Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice

Form No. Z2285

2

Rev. 10.05.10

Image 2
Contents Installation and Operation Instructions Table of ContentsGeneral Information Narrow Door Back Bar Cabinets Cleaning the Cabinet Refrigeration and Temperature ControlAdjusting the Temperature Cleaning the CondenserStainless Steel Remember Models Reversing door hinge Narrow Door Back Bar Cabinets Operations to Perform on CabinetWiring diagram NS Series Cabinets Wiring DIAGRAm NR Series Cabinets Form No. Z2285 Rev Form No. Z2285 West Good Hope Road MILWAUKEE, Wisconsin