2.0 SCOPE
The information contained within this manual covers the installation and operation of Pelco
Installation should be in accordance with all applicable local and national electric codes, utilizing approved materials only.
Please thoroughly familiarize yourself with the infor- mation in this manual prior to installation and opera- tion.
3.0 DESCRIPTION
Pelco’s
The
The
Models with the letters “LPP” in the part number are equipped with potentiometers for the zoom and focus drive motors, providing a means for preset positioning commands from a microprocessor based control unit to automatically drive zoom and focus functions.
4.0INSTALLATION
4.1CABLE DISTANCES
The following distances are for reference only and are the approximate maximum recommended under the fol- lowing conditions:
—30mA maximum at 12 VDC
—Single lens function activation
—Single common conductor in lens cable
—10% loss in voltage
22 Awg to 1,236 feet (377 m)
20 Awg to 1,968 feet (600 m)
18 Awg to 3,133 feet (955 m)
16 Awg to 4,974 feet (1,516 m)
NOTE: Video limited to 500 feet on
4.2 WIRING
4.2.1 TVJ6AC-1 Motorized Zoom Lens
This lens features a spot filter and internal
The
4.2.1.1 Wiring Pinouts
Wiring is as follows:
|
|
|
| Connector |
Function | Color |
| Pin Number | |
|
|
|
|
|
Zoom | Green |
| 2 | |
Focus | White |
| 3 | |
Common | Black & Red |
| 4 | |
|
|
|
|
|
|
|
|
|
|
Small |
|
|
|
|
| Auto Iris Cable | |||
|
|
| ||
Red wire |
| VCC (+9 to +18 VDC) | ||
Black wire |
| Ground | ||
White wire |
| Video Signal | ||
Green wire |
| VCC (+9 to +18 VDC) | ||
|
|
|
|
|
*Plug for this cable is provided with the camera.