Pelco EH8000 operation manual Specifications Electrical, General, Environmental

Page 5

3.0SPECIFICATIONS ELECTRICAL

Input Voltage: 120 VAC (230 VAC optional) for heaters

Power Requirements:

40 watts (EH8004)

160 watts (all other models)

Connector: Souriau 85107E2016P, 16-pin jam nut receptacle

Mating

Connector: Souriau 85106EC2016S, MS type

connector (supplied)

Maximum

 

 

Cable Distances:

 

 

Wire

 

 

Gauge

EH8004

All Others

1210,390 ft (3167 m) 2,640 ft (805 m)

146,560 ft (1999 m) 1,660 ft (506 m)

164,110 ft (1253 m) 1,040 ft (317 m)

18

2,590 ft

(789 m)

650 ft (198 m)

20

1,620 ft

(494 m)

410 ft (125 m)

Heater:

EH8004, one (1) 40 watt, 120/230

 

VAC; all others two (2) 80 watt,

 

120/230 VAC

 

GENERAL

 

 

 

Construction: Aluminum 6061 T6

 

Finish:

 

 

 

Outside

Gray polyester powder coat

Inside

Black anodized

 

Dimensions:

See Figure 1

 

Front Window:

EH8004 3.75" (9.52 cm) diameter tempered glass, 0.225" (0.57 cm) thick

EH8006 6" (15.24 cm) diameter tempered glass, 0.225" (0.57 cm) thick

EH8008 8" (20.32 cm) diameter tempered glass, 0.225" (0.57 cm) thick

Camera

Mounting: Custom designed depending on camera/lens

Maximum

 

 

Camera/Lens

 

 

Size:

 

 

EH8004

3.75" (9.53 cm) diameter x 14"

 

(35.56 cm) long or

 

 

14"L x 2.8"W x 2.8"H

 

(35.56 cm x 7.11 cm x 7.11 cm)

EH8006

5.75" (14.61 cm) diameter x 18"

 

(45.72 cm) long or

 

 

18"L x 4.25"W x 4.25"H

 

(45.72 cm x 10.80 cm x 10.80 cm)

EH8006-26

5.75" (14.61 cm) diameter x 24"

 

(60.96 cm) long or

 

 

24"L x 4.25"W x 4.25"H

 

(60.96 cm x 10.80 cm x 10.80 cm)

EH8008

7.75" (19.69 cm) diameter x 24"

 

(60.96 cm) long or

 

 

24"L x 5.65"W x 5.65"H

 

(60.96 cm x 14.35 cm x 14.35 cm)

Enclosure

 

 

Mounting:

Adjustable cradle

secured with

 

stainless steel bands

Weight:

 

 

Model

Unit

Shipping

EH8004

10 lbs (4.54 kg) 12 lbs (5.44 kg)

EH8006

24 lbs (10.89 kg) 26 lbs (11.79 kg)

EH8006-26

32 lbs (14.51 kg) 34 lbs (15.42 kg)

EH8008

45 lbs (20.41 kg) 47 lbs (21.32 kg)

ENVIRONMENTAL

Ambient

Operating

Temperature: -40°to 122°F (-40°to 50°C)

(with heater)

Vibration:

5 to 60 Hz with 0.082-inch (0.21 cm)

 

total travel (15 g’s at 60 Hz). From

 

60 to 1,000 Hz, 5 g’s rms with

 

random vibration

Altitude:

Sea level to equivalent of 10,000

 

feet (3,048 m)

Acoustic

 

Noise:

Operates in 150 dB acoustic noise

 

environments

Humidity:

MIL-E-540T, para. 3.2.24.7. Up to

 

100% relative humidity. Equipped

 

with standard Schraeder and pres-

 

sure relief valves to provide positive

 

internal pressure with dry nitrogen.

Pelco Manual C418M (8/97)

3

Image 5
Contents EH8000 Series List of Illustrations Table of ContentsDescription ScopeModel Numbers Optional AccessoriesRecommended Mounts Recommended ControlsEnvironmental Specifications ElectricalGeneral Enclosure Mounting Fixed InstallationTypical Fixed Wall Mounting Enclosure Mounting PAN/TILTMating Connector Assembly CAMERA/LENS Installation and AdjustmentsPage Page Page Troubleshooting Guidelines SUN Shroud InstallationMaintenance Enclosure DisassemblyRecharging the Enclosure Enclosure ServicingEH8004 Mechanical Parts List Exploded Assembly DiagramEH8000 Series Enclosures Mechanical Parts List 10.0 EH8000 Series Enclosures Electrical Parts List EH8006, EH8006-26 Mechanical Parts ListEH8008 Mechanical Parts List Returns Warranty and Return Information