3.1.3 Mounting the Hanger Assembly

NOTE: When determining the mounting location, consideration must be given to the total weight of the monitor and the mount. The mounting surface must be adequate to support this weight.

1.Determine the location for, and the type of mount to be used. Remember to allow for adequate clearance on all sides of the monitor.

2.Use the adapter mount as a template to mark the required mounting holes.

3.Using the necessary fasteners, attach the adapter mount to the chosen sur- face.

4.Thread the mounting pipe into the mount, stopping at the desired position, after the threads have become tight (approximately 30 ft lb). (If the MRCA or MRWA is being used, tighten the 8-32 screw in the pipe nut to lock the pipe threads.)

3.1.4Monitor Mounting

1.Set the monitor assembly into the mounted hanger assembly.

2.Align the threaded inserts in the monitor brackets with the slots in the pan bracket.

3.Secure the monitor assembly to the hanger assembly with the #10 screws, lockwasher, and flat washers supplied. (See Figure 2)

4.Tilt the monitor to the desired angle and tighten the 1/2-13 hex bolts.

5.Make all necessary electrical connections.

4

Pelco Manual C233M-G (8/95)

Image 8
Contents MR4000/MRU Contents Revision History List of IllustrationsList of Tables 12iv Pelco Manual C233M-G 8/95 Product and/or manual may bear the following mark Important Safeguards and WarningsGeneral Description Installation MR4000 AssemblyMonitor Assembly See Figure Hanger Assembly See FigureMounting the Hanger Assembly Monitor MountingMRU Assembly Instructions Hanger AssemblyExploded Assembly ZH10LWSSLSpecifications Dimension DrawingsWarranty and Return Information Warranty