CV-A11
7.2. CV-A11 RS-232C command list.
|
| Command Name | Format |
| Parameter |
|
| Remarks | |
|
| A – | General settings and | useful commands |
|
|
|
| |
EB |
| Echo Back | EB=[Param.]<CR><LF> | 0=Echo off | 1=Echo on |
| Off at power up | ||
ST |
| Camera Status request | ST?<CR><LF> |
|
|
| Actual setting | ||
HP |
| Online Help request | HP?<CR><LF> |
|
|
| Command list | ||
VN |
| Firmware version | VN?<CR><LF> |
|
|
| 3 letter version | ||
| B – Timing and shutter related commands |
|
|
|
| ||||
SC |
| Scanning format | SC=[Param.]<CR><LF> | 0=full frame | 1=1/2 partial |
|
| ||
|
|
|
|
|
| 2=1/3 partial | 3=1/6 partial |
|
|
TR |
| Trigger mode | TR=[Param.]<CR><LF> | 0=normal | 1=Edge |
|
| ||
|
|
|
|
|
| 2=Pulse width | 3=Frame delay |
|
|
|
|
|
|
|
| 4=Long time | 5=Start/stop |
|
|
|
|
|
|
|
| 6=Smearless |
|
|
|
SM |
| Shutter mode | SM=[Param.]<CR><LF> | 0=Normal | 1=Programmab. |
|
| ||
SH |
| Shutter speed | SH=[Param.]<CR><LF> | 0=1/30 | 1=1/50 |
| All15 step is valid | ||
|
|
|
|
|
| 2=1/60 | 3=1/125 |
| in normal trigger |
|
|
|
|
|
| 4=1/250 | 5=1/500 |
| mode. |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
| 6=1/1000 | 7=1/2000 |
| In all trigger |
|
|
|
|
|
| 8=1/4000 | 9=1/10,000 |
| modes shutter |
|
|
|
|
|
| 10=1/20,000 | 11=1/40,000 |
| speeds higher |
|
|
|
|
|
| 12=1/60,000 | 13=1/80,000 |
| than 9 will result |
|
|
|
|
|
|
| in 1/10,000 | ||
|
|
|
|
|
| 14=1/100,000 |
|
|
|
PE |
| Programmable expos. | PE= Param. <CR><LF> | 0=*1), 1=1.5H | 1023=1023.5 H |
|
| ||
|
|
|
| [ | ] |
|
|
| H= 63.56∝sec |
|
|
|
|
|
|
|
| ||
HC |
| HD accumulation | HC=[Param.]<CR><LF> | 0=H synchron |
| ||||
|
|
|
|
|
| accumulation | accumulation |
| TR=2 and TR=3 |
| C – Signals and polarity |
|
|
|
|
|
| ||
SO |
| Sync signal | SO=[Param.]<CR><LF> | 0=no sync | 1=sync on video |
|
| ||
CW |
| Clock/WEN | CW=[Param.]<CR><LF> | 0= WEN out | 1=Clock out |
| CW=0 if clock not | ||
|
|
|
|
|
|
|
|
| used |
TP |
| Trigger polarity | TP=[Param.]<CR><LF> | 0= active low | 1= active high |
| *2) | ||
WP |
| WEN polarity | WP=[Param.]<CR><LF> | 0= active low | 1= active high |
|
| ||
| D – Gain and analogue signals setting |
|
|
|
|
| |||
AS |
| AGC Switch | AS=[Param.]<CR><LF> | 0=AGC off | 1=AGC on |
| 0= manual gain | ||
AG |
| AGC Level | AG=[Param.]<CR><LF> | 0=low | 255=high |
| Range 0 to 255 | ||
GA |
| Manual gain Level | GA=[Param.]<CR><LF> | 0=low | 255=high |
| Range 0 to 255 | ||
RP |
| Rear Potentiometer | RP=[Param.]<CR><LF> | 0=manual gain | 1=rear potm. |
|
| ||
SU |
| Setup Level | SU=[Param.]<CR><LF> | 0=low | 255=high |
| Range 0 to 255 | ||
WC |
| White clip Level | WC=[Param.]<CR><LF> | 0=low | 255=high |
| Range 0 to 255 | ||
GS |
| Gamma Select | GS=[Param.]<CR><LF> | 0=gamma 1 | 1=gamma 0.45 |
|
| ||
| E – Saving and loading data in EEPROM |
|
|
|
| ||||
LD |
| Load settings from | LD=[Param.]<CR><LF> | 0=Factory data | 1=User 1 area |
| Latest used data | ||
|
| camera EEPROM |
|
| 2=User 2 area | 3=User 3 area |
| area becomes | |
|
|
|
|
|
|
|
|
| default at next |
|
|
|
|
|
|
|
|
| power up |
SA |
| Save settings to | SA=[Param.]<CR><LF> | 1=User 1 area | 2=User 2 area |
|
| ||
|
| camera EEPROM |
|
| 3=User 3 area |
|
|
| |
*1) |
| PE=0 has no function in triggered mode. PE=1 is 0.5H in continuous mode |
|
|
| ||||
*2) |
| If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. |
|
|
!!Do not try to use commands not shown in the list.
- 18 -