JAI operation manual CV-A11 RS-232C command list, Useful commands

Page 19

CV-A11

7.2. CV-A11 RS-232C command list.

 

 

Command Name

Format

 

Parameter

 

 

Remarks

 

 

A –

General settings and

useful commands

 

 

 

 

EB

 

Echo Back

EB=[Param.]<CR><LF>

0=Echo off

1=Echo on

 

Off at power up

ST

 

Camera Status request

ST?<CR><LF>

 

 

 

Actual setting

HP

 

Online Help request

HP?<CR><LF>

 

 

 

Command list

VN

 

Firmware version

VN?<CR><LF>

 

 

 

3 letter version

 

B – Timing and shutter related commands

 

 

 

 

SC

 

Scanning format

SC=[Param.]<CR><LF>

0=full frame

1=1/2 partial

 

 

 

 

 

 

 

 

2=1/3 partial

3=1/6 partial

 

 

TR

 

Trigger mode

TR=[Param.]<CR><LF>

0=normal

1=Edge

 

 

 

 

 

 

 

 

2=Pulse width

3=Frame delay

 

 

 

 

 

 

 

 

4=Long time

5=Start/stop

 

 

 

 

 

 

 

 

6=Smearless

 

 

 

SM

 

Shutter mode

SM=[Param.]<CR><LF>

0=Normal

1=Programmab.

 

 

SH

 

Shutter speed

SH=[Param.]<CR><LF>

0=1/30

1=1/50

 

All15 step is valid

 

 

 

 

 

 

2=1/60

3=1/125

 

in normal trigger

 

 

 

 

 

 

4=1/250

5=1/500

 

mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6=1/1000

7=1/2000

 

In all trigger

 

 

 

 

 

 

8=1/4000

9=1/10,000

 

modes shutter

 

 

 

 

 

 

10=1/20,000

11=1/40,000

 

speeds higher

 

 

 

 

 

 

12=1/60,000

13=1/80,000

 

than 9 will result

 

 

 

 

 

 

 

in 1/10,000

 

 

 

 

 

 

14=1/100,000

 

 

 

PE

 

Programmable expos.

PE= Param. <CR><LF>

0=*1), 1=1.5H

1023=1023.5 H

 

 

 

 

 

 

[

]

 

 

 

H= 63.56sec

 

 

 

 

 

 

 

 

HC

 

HD accumulation

HC=[Param.]<CR><LF>

0=H synchron

1=a-synchron

 

a-sync. only for

 

 

 

 

 

 

accumulation

accumulation

 

TR=2 and TR=3

 

C – Signals and polarity

 

 

 

 

 

 

SO

 

Sync signal

SO=[Param.]<CR><LF>

0=no sync

1=sync on video

 

 

CW

 

Clock/WEN

CW=[Param.]<CR><LF>

0= WEN out

1=Clock out

 

CW=0 if clock not

 

 

 

 

 

 

 

 

 

used

TP

 

Trigger polarity

TP=[Param.]<CR><LF>

0= active low

1= active high

 

*2)

WP

 

WEN polarity

WP=[Param.]<CR><LF>

0= active low

1= active high

 

 

 

D – Gain and analogue signals setting

 

 

 

 

 

AS

 

AGC Switch

AS=[Param.]<CR><LF>

0=AGC off

1=AGC on

 

0= manual gain

AG

 

AGC Level

AG=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

GA

 

Manual gain Level

GA=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

RP

 

Rear Potentiometer

RP=[Param.]<CR><LF>

0=manual gain

1=rear potm.

 

 

SU

 

Setup Level

SU=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

WC

 

White clip Level

WC=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

GS

 

Gamma Select

GS=[Param.]<CR><LF>

0=gamma 1

1=gamma 0.45

 

 

 

E – Saving and loading data in EEPROM

 

 

 

 

LD

 

Load settings from

LD=[Param.]<CR><LF>

0=Factory data

1=User 1 area

 

Latest used data

 

 

camera EEPROM

 

 

2=User 2 area

3=User 3 area

 

area becomes

 

 

 

 

 

 

 

 

 

default at next

 

 

 

 

 

 

 

 

 

power up

SA

 

Save settings to

SA=[Param.]<CR><LF>

1=User 1 area

2=User 2 area

 

 

 

 

camera EEPROM

 

 

3=User 3 area

 

 

 

*1)

 

PE=0 has no function in triggered mode. PE=1 is 0.5H in continuous mode

 

 

 

*2)

 

If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.

 

 

!!Do not try to use commands not shown in the list.

- 18 -

Image 19
Contents CV-A11 CV-A11 Table of ContentsGeneral Main FeaturesStandard Composition Camera Housing and Dimensions Pin Multi-connector Trigger and RS232C Pin Multi-connector DC-IN/VIDEO OUT, EXT.HD/VDPin Assignment HD and VD input Input and Output CircuitsVideo output Trigger inputBasic functions Functions and OperationsContinuous Operation Non triggered Input-output of HD/VD SignalsEdge Pre-select Mode.TR=1 External Trigger ModesImportant notes on using this mode Edge Pre-select ModePulse width control Pulse Width Control ModeFrame delay read out Frame-delay read out ModeLong time exposure Long Time Exposure ModeStart/stop mode Start/Stop ModeSmearless mode Smearless ModeReadout format Frame rate Effective lines Partial scan readout modeOther Functions RS-232C control Configuring the CameraUseful commands CV-A11 RS-232C command listCamera Control Tool for CV-A11 Selecting termination of HD/VD input signals Internal Switch and Jumper Settings1. HD/VD input-output selection Spectral Sensitivity SpecificationsAppendix WEN out on pin 6 on 6 pin connectorCV-A11 emulating CV-M10 interfacing Typical CCD Characteristics PrecautionsCamera type CV-A11 Revision Revision a Serial No …………… Users Record