7. Configuring the Camera

7.1. RS-232C control.

All configuration of the CV-A11 camera is done via the RS-232C port. The camera can be set up from a PC running terminal emulator software, or using JAI´s camera control software.

Below is the description of the ASCII based short command protocol.

Communication setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Baud Rate

9600 bps

 

 

 

 

 

 

 

1 CD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 DTR

 

 

Data Length

8 bit

 

 

 

 

 

 

 

 

 

RS 232C cable

 

 

 

 

 

 

6 DSR

9 pin

 

 

 

 

 

 

 

 

Start Bit

1 bit

 

TXD

 

 

 

 

2 RXD

 

CAMERA

 

 

 

 

D-con

 

 

 

 

RXD

 

 

 

3 TXD

PC COM

 

 

 

 

 

 

 

Stop Bit

1 bit

 

 

 

 

GND

5 GND

 

 

 

 

 

 

 

 

 

 

7 RTS

PORT

 

Parity

None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8 CTS

 

 

 

 

 

 

 

 

 

 

 

Xon/Xoff Control

None

 

 

 

 

 

 

 

9 CI

 

Fig. 24. RS-232C cable.

Protocol.

Transmit setting to camera:

NN=[Parameter]<CR><LF> (NN is any kind of command. Capital or small letters.)

To have all communication visible on the emulator screen, start with:

EB=1<CR><LF>

The camera answers:

COMPLETE<CR><LF>

Transmit the following to see the current parameter for a command:

NN?<CR><LF> (NN is any commands with parameters.)

The camera answers: NN=[Parameter]

Transmit the following to see the current camera settings:

ST?<CR><LF>

The camera returns the current parameter settings.

Transmit the following to get command list help:

HP?<CR><LF>

The camera returns a complete command list.

Unknown commands send to camera: (XY is unknown command).

XY=1<CR><LF>

The camera answers: 01 Unknown Command!!<CR><LF>

Invalid parameters send to camera: (99 is invalid parameter for SH).

SH=99<CR><LF>

The camera answers: 02 Bad Parameters!!<CR><LF>

- 17 -

Image 18
Contents CV-A11 Table of Contents CV-A11Main Features GeneralStandard Composition Camera Housing and Dimensions Pin Multi-connector DC-IN/VIDEO OUT, EXT.HD/VD Pin Multi-connector Trigger and RS232CPin Assignment Trigger input Input and Output CircuitsVideo output HD and VD inputFunctions and Operations Basic functionsInput-output of HD/VD Signals Continuous Operation Non triggeredExternal Trigger Modes Edge Pre-select Mode.TR=1Edge Pre-select Mode Important notes on using this modePulse Width Control Mode Pulse width controlFrame-delay read out Mode Frame delay read outLong Time Exposure Mode Long time exposureStart/Stop Mode Start/stop mode Smearless Mode Smearless modePartial scan readout mode Readout format Frame rate Effective linesOther Functions Configuring the Camera RS-232C controlCV-A11 RS-232C command list Useful commandsCamera Control Tool for CV-A11 Internal Switch and Jumper Settings Selecting termination of HD/VD input signals1. HD/VD input-output selection Specifications Spectral SensitivityWEN out on pin 6 on 6 pin connector AppendixCV-A11 emulating CV-M10 interfacing Precautions Typical CCD CharacteristicsUsers Record Camera type CV-A11 Revision Revision a Serial No ……………