User’s Manual
<DELETE> and press <ENTER> to delete the selected character.
STEP7: When the setting is completed, move the cursor to <SAVE> and press <ENTER> to save.
3.3.12ALARM SETTING
The integrated high speed dome provides eight alarm inputs and two alarm outputs (N.O. and N.C) to connect alarm devices. With this function, dome will cooperates with alarm system to catch the event images. For wiring, please refer to the installation guide and/or qualified service personnel. Alarm parameters can be set on this page.
ALARM SETTING |
|
ALARM PIN | 1 |
ALARM SWITCH | OFF |
ALARM TYPE | N.C. |
ALARM ACTION | PRESET |
PRESET POINT | 001 |
DWELL TIME | ALWAY |
EXIT | YES |
•ALARM PIN
The dome provides 8 alarm inputs and 2 outputs (1× N.O. and 1× N.C.). Select an alarm connector which you want to set its
•ALARM SWITCH
The item is used to enable or disable the selected alarm pin function. Use the left/right direction keys on the control keyboard to change the setting.
•ALARM TYPE
There are two kinds of alarm types: Normal Open and Normal Close, which are illustrated as below. Select an alarm type that corresponds with the alarm application.
26