User’s Manual
manually by selecting this item.
•EXIT
Exit the HOME SETTING menu.
3.3.14SEQUENCE
The function executes
SEQUENCE |
|
SEQUENCE LINE | 1 |
SEQUENCE POINT | 01 |
PRESET POSITION | 001 |
SPEED | 1 |
DWELL TIME | 001 |
RUN SEQUENCE | ENTER |
EXIT | YES |
•SEQUENCE LINE
There are eight sets of sequence lines built in the dome camera. Using LEFT/RIGHT direction keys to select a line first and then set its sequence points.
•SEQUENCE POINT
Up to 32 points can be specified for each sequence line. The sequence points represent the orders of the preset points that the dome will automatically run, and the bellowing setup items; PRESET POSITION, SPEED, and DWELL TIME, are related to this item.
•PRESET POSITION
Users can assign a specific preset position to the selected sequence point with this item.
•SPEED
Users can set the Speed that the dome goes to the next sequence point, and the setup speed range is from 1 ~ 15. Refer to below table for more information.
|
| PAN (degree/sec.) | TILT (degree/sec.) |
|
| Speed 1 | 10 | 8 |
|
| Speed 2 | 23 | 12 |
|
| Speed 3 | 35 | 22 |
|
|
|
|
|
|
29