Setting the Starting Address

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a start address from 1~512. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that uses six DMX channels and was addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap, and note the start address selected for future reference.

If this is your first time addressing a fixture using the DMX control protocol, we suggest jumping to the “Appendix” section and reading the heading “DMX Primer”. It contains very useful information that will help you understand its use.

General Troubleshooting

SYMPTOM

POSSIBLE CAUSE(S)

POSSIBLE ACTION(S)

Breaker/Fuse

Excessive circuit load

Check total load placed on the electrical circuit.

Short circuit along the power

Check for a short in the electrical wiring (internal and/or

keeps blowing

 

wires

external).

 

 

 

Device does not

No power

Check for power on Mains.

 

 

power up

Loose power cord

Check power cord

 

 

Wrong DMX addressing

Check Control Panel and unit addressing

 

Damaged DMX cables

Check DMX cables

Fixture is not

Wrong polarity settings on the

Check polarity switch settings on the controller

controller

 

responding to

 

 

 

DMX

Loose DMX cables

Check cable connections

 

 

Faulty DMX interface

Replace DMX input

 

Faulty Main PCB

Replace Main PCB

 

 

 

 

Non DMX cables

Use only DMX compatible cables

 

Bouncing signals

Install terminator as suggested.

Loss of signal

Long cable / Low level signal

Install amplifier right after fixture with strong signal.

 

 

 

Too many fixtures

Install an optically coupled DMX splitter after unit #32.

 

Interference from AC wires

Keep DMX cables separated from power cables or

 

 

black lights.

 

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET Technical Support.

Contact Us

W o r ld W ide

General Information

CHAUVET

 

3000 North 29th Court

 

Hollywood, FL 33020

 

voice:

954.929.1115

 

fax:

954.929.5560

 

toll free: 800.762.1084

Technical Support

CHAUVET

 

3000 North 29th Court

 

Hollywood, FL 33020

 

voice:

954.929.1115 (Press 4)

 

fax:

954.929.5560 (Attention: Service)

World Wide Web

www.chauvetlighting.com

4. Operating Instructions

15

10/27/2009 1:10 PM

Image 15
Contents Snapshot Table of Contents Manual Conventions What is includedBefore YOU Begin Unpacking InstructionsSafety Instructions Product Overview FeaturesAdditional Features IntroductionPhotometrics Product Overview Setup AC PowerPower Linking Mounting OrientationRigging DMX Data Cable Cable ConnectorsFixture Linking Data CablingPin to 5-Pin Conversion Chart Setting up a DMX Serial Data LinkStrobe Speed Accessing the 2 PersonalitiesMaster/Slave Mode Sound-Active, Auto Mode, Static Colors Operating InstructionsStatic Colors Standalone OperationAutomatic Sound-ActiveDMX Channel Values CH ModeSetting the Starting Address General TroubleshootingContact Us General Maintenance AppendixDMX Primer Claims Returns ProcedurePower Technical Specifications