Configuration
NOTE
A speaker with amplifier inside shall be connected to AUDIO out jack on rear panel.
7.4.2Motion detection settings
The setting is similar to alarm input with some additional functions:
zMotion detection
–Set on, open motion detection function.
–Default is off, close motion detection function.
zArea
–Click “Set motion area”, an image screen will pop up.
–Select the interested area by dragging the mouse.
zSensitivity
Set "Sensitivity."
–High: An alarm will be triggered with even small changes in brightness within the defined area.
–Mid: Intermediate between High and Low.
–Low: An alarm will be triggered with a major change in brightness within the defined area.
zText Enable
–Select ON or OFF to define whether an additional alarm text defined in the Text field is to be overlaid on the video image.
zText
–Define an individual text for alarm overlay.
zAudio Output
–Select ON or OFF to define whether an additional audio message (*.wav),
zEvent
| 35 |
|
|
Siemens Building Technologies |
|
Fire Safety & Security Products | 01.2009 |