Configuration

zRecording by Alarm

Configure "Alarm input setting" first.

Then select the recording format:

Record source: choose JPEG or MPEG4 format

Record frame

Set the number of images to be recorded immediately after an alarm occurs. Images of the moment when an alarm occurs are not included.

1, 2, 5, 10, 30 and 60 frames can be selected if JPEG format selected. No need for MPEG4 format

Recording cycle

Set a time interval for alarm recording 1, 2, 5, 10, 30, 60, 90, 120 s can be selected for JPEG format, no need for MPEG4 format

Recording time:

If MPEG4 selected, the recording time can be set to 2, 5, 10 s.

Record file name

Under transfer image section, the file name arranged by FTP server is time stamp based. With Time Stamp based, the record file name will be formatted with the desired file name, time and date as the file name. You can enter the file name or leave it blank.

zRecording by Motion

Configure "Motion Detection Setting" first.

All the other settings are same as recording by alarm as above.

FTP Server Settings - Server 1 and 2

Please follow your FTP setting to setup FTP server name, Login ID, Password,

FTP port number, FTP mode, and FTP connecting method.

38

Siemens Building Technologies

 

Fire Safety & Security Products

01.2009

Image 38
Contents CFMC1315-LP Contacting us CopyrightTrademarks Training coursesContents 10.1 Page Page Installation SafetyGeneral safety precautions Target readersCleaning Meaning of the signal wordsMeaning of the hazard symbols Damage due to unsuitable mounting locationEU directives European Directive 2004/108/EC Electromagnetic CompatibilitySpecifications Image System DescriptionPackage Contents Ordering DataCamera part and connector definition Camera part definitionPower in connector Alarm out terminalAlarm in terminal 6 IP/TV switch Reset buttonPower adaptor Installing the cameraPrecautions SD Memory cardSwitch Setting Network Camera EnvironmentSpecifications Concept of the Network CameraIP Address Connecting the Camera and Personal Computer by NetworkConnection Configuration Connecting Camera and Personal Computer Click the Home page of selected device button Using the Camera Search Application IpFinderSetting up IpFinder Using the Camera Search Application Web cam IP manager Ssdp Simple Service Discovery Protocol / network protocolViewing and Listening Administrator Log-inLog-in Screen Preparations before displayingBrowser setting when proxy server is used Log-in the cameraCamera Image Screen Components of unit homeCompression ConfigurationImage mode Unicast Streaming Multicast StreamingHow to operate Rtsp Then fill in rtsp//IP addressrtspport/livestream Network Settings in the Configuration menu Network SettingsBasic Settings Ddns Settings FTP ServerImage Colour Camera Basic settingsImage Parameters Picture Camera-mask zone settings Camera-Cropping settings Camera-OSD settings Alarm External digital inputMotion detection settings Alarm output Audio EventFTP recording conditions RecordFTP recording FTP Server Settings Server 1 Connecting method SD Card Back Up if FTP FailSD recording Configuration Authentication setting Emailing recordingCondition settings for sending e-mail by motion Condition settings for sending e-mail by scheduleCondition settings for sending e-mail by alarm Mail to Address List NAS recording Configuration Audio output AudioAudio input Date/Time Access protection Password AdministratorAdministrator Functions User listForbidden Ports FirewallIP Adress Filter Forbidden Protocol SettingSystem Update ConfigurationTemperature Information 11 LogEvent Log Utility program application NAS player setupAudio record setup Playing back NAS fileFirmware update setup Perform firmware update in the following sequenceMaintenance DisposalKeyword index JpegKeyword index Page A6V10236128