Maintenance

Changing flash tube and/or modeling lamp

1.Ensure that the D1 unit is turned off and that the power cable is not connected.

2.If the unit has been in use, wait five minutes to allow the unit to be fully discharged.

3.Gently remove the frosted glass plate.

4.Change the flash tube:

Unlock the flash tube trigger by unfolding the stainless steel ribbons around the clasp.

Grasp the flash tube in the bottom and pull it straight out of the socket.

When inserting the new flash tube, ensure that the trigger connection clasps properly around the flash tube.

Lock the flash tube trigger by folding the stainless steel ribbons around the clasp.

5.Change the modeling lamp:

Pull the lamp straight out of the socket.

Insert a new modeling lamp, straight into the socket. Do not touch the lamp with bare hands.

6.Carefully fit the glass plate in place, with the frosted side inwards. Make sure that the safety pins fit properly around the glass plate.

Profoto D1

17

Clasp

Flash tube

Modeling lamp

www.profoto.com

Image 17
Contents D1 1000 Air D1 500 Air D1 250 Air Profoto D1 Thank you for choosing Profoto Safety Precautions Safety instructionsTable of Contents Profoto Air System descriptionProfoto Air Sync Profoto Air RemoteProfoto Air USB Profoto Studio AirNomenclature Slave SettingSync Connector Locking Knob Sync signaling Power supplyFunctionality Energy controlFlash before ready Ready signalingReady indicator/Test function Color temperature Remote controlReflector UmbrellaOperating instructions Ready signaling setting Modeling light settingSync via cable Radio settings D1 with Profoto AirSync via IR Sync via radio D1 without Profoto AirTurn off unit Clasp Flash tube Modeling lamp MaintenanceChanging flash tube and/or modeling lamp Changing built-in fuse Adaptive thermal control 500 Air 1000 Air250 Air 500Synchronization modes Sync cable/IR/Air This page is intentionally left blank This page is intentionally left blank Change without notice