Connecting to Power
The recommended adaptor specification for
When the resistance value of copper wire is at [20°C(68°F)]
Copper wire size(AWG) | #24(0.22mm2) | #22(0.33mm2) #20(0.52mm2) | #18(0.83mm2) | |
Resistance value(Ω/m) | 0.078 | 0.050 | 0.030 | 0.018 |
Voltage drop(V/m) | 0.028 | 0.018 | 0.011 | 0.006 |
•As shown in the table above, voltage decreases as the wire gets longer. Therefore use of an excessively long adaptor output line for connection to the camera may affect the performance of the camera.
Standard voltage for camera operation : DC 12V±10%
There may be some deviation in voltage drop depending on the type of wire and the manufacturer.
Note
•Please must be used adaptor that meets the standard requirement.
•Please connect the power after installation.
RS-485 communication control
Connecting to RS-485 CONTROL TERMINAL
CONTROL TERMINAL | SPEC |
WHITE (TRX+) | |
BLACK |
Using a
(1)The case which it controls from the PC
Using a
EX) SERIAL PORT OF THE PC(COM1) — SERIAL CABLE
--
(2)The case which it controls from the DVR or System Controller
It connects the
485 CONTROL BOARD CONNECTION TERMINAL | |
(+)CONNECTION TERMINAL | WHITE (TRX+) |
BLACK |
Notes
•When you construct external control systems for a camera control, please use to the
•When you connecting to
COLOR IR CAMERA 16 User’s Manual | COLOR IR CAMERA 17 User’s Manual |